Articles & Issues
- Language
- English
- Conflict of Interest
- In relation to this article, we declare that there is no conflict of interest.
- This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.
All issues
A Simple Method to Determine the Adsorption Isotherm of Taxol from a Yew Tree
Department of Chemical Engineering, Inha University, Inchon 402-751, Korea
rowkho@dragon.inha.ac.kr
Korean Journal of Chemical Engineering, May 1999, 16(3), 388-391(4), 10.1007/BF02707130
Download PDF
Abstract
Taxol, a powerful anticancer agent, was extracted from yew extract and separated by NP-HPLC (Normal-Phase High Performance Liquid Chromatography). At the mobile phase composition of hexane/IPA/MeOH, 90/4/6 vol%, taxol was preparatively separated in a chromatographic column with large packings (15 μm). The purified taxol was used to determine the adsorption isotherm of taxol. From the experimental results, the adsorption isotherm was obtained as the following Langmuir type,
Cs=59.5CM/1+2.0CM
To obtain the adsorption isotherm, only two injections of a small and large amount of taxol were required, and the Langmuir adsorption parameters were calculated from the assumption of monolayer coverage on the solid surface.
Cs=59.5CM/1+2.0CM
To obtain the adsorption isotherm, only two injections of a small and large amount of taxol were required, and the Langmuir adsorption parameters were calculated from the assumption of monolayer coverage on the solid surface.
References
Cardellina JH, J. Liquid Chromatogr., 14, 659 (1991)
Chang KK, Park YK, Row KH, Chung ST, Chem. Ind. Technol., 16, 1 (1998)
Chang KK, Row KH, Chung ST, J. Korean Ind. Eng. Chem., 8(2), 286 (1997)
Hadden N, Baumann F, MacDonald F, Munk M, Stevenson R, Gere D, Zamaroni F, Majors R, "Basic Liquid Chromatography," Varian Aerograph (1971)
Jandera P, Posvec Z, Vraspir P, J. Chromatogr. A, 734, 125 (1996)
Jung YA, Chung ST, Row KH, HWAHAK KONGHAK, 35(5), 712 (1997)
Rao KV, Reddy GC, Juchum J, Physicochemistry, 43, 439 (1996)
Snyder LR, Cox GB, Antle PE, Chromatographia, 24, 82 (1987)
Sofer G, Hagel L, "Handbook of Process Chromatography: A Guide to Optimization, Scale up, and Validation," Academic Press, San Diego (1997)
Wu DR, Lohse K, Greenblatt HC, J. Chromatogr. A, 702, 233 (1995)
Chang KK, Park YK, Row KH, Chung ST, Chem. Ind. Technol., 16, 1 (1998)
Chang KK, Row KH, Chung ST, J. Korean Ind. Eng. Chem., 8(2), 286 (1997)
Hadden N, Baumann F, MacDonald F, Munk M, Stevenson R, Gere D, Zamaroni F, Majors R, "Basic Liquid Chromatography," Varian Aerograph (1971)
Jandera P, Posvec Z, Vraspir P, J. Chromatogr. A, 734, 125 (1996)
Jung YA, Chung ST, Row KH, HWAHAK KONGHAK, 35(5), 712 (1997)
Rao KV, Reddy GC, Juchum J, Physicochemistry, 43, 439 (1996)
Snyder LR, Cox GB, Antle PE, Chromatographia, 24, 82 (1987)
Sofer G, Hagel L, "Handbook of Process Chromatography: A Guide to Optimization, Scale up, and Validation," Academic Press, San Diego (1997)
Wu DR, Lohse K, Greenblatt HC, J. Chromatogr. A, 702, 233 (1995)