articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

On-Site Diagnostic Device Based on Immuno-Separation of Proteins

1Graduate School of Biotechnology, Korea University, 15-ka, Anam-dong, Sungbuk-ku, Seoul 136-701, Korea 2Bio-Microsystem Program, Korea University, 15-ka, Anam-dong, Sungbuk-ku, Seoul 136-701 3Bio-Microsystem Program, Korea University, 15-ka, Anam-dong, Sungbuk-ku, Seoul 136-701, Korea
shpaek@tiger.korea.ac.kr
Korean Journal of Chemical Engineering, March 2001, 18(2), 263-269(7), 10.1007/BF02698469
downloadDownload PDF

Abstract

A membrane immuno-chromatographic system that selectively separates plasma lipoproteins and generates a signal in proportion to the concentration of cholesterol (HDL-C) within high-density lipoprotein (HDL) was investigated as a point-of-care device for the prognosis of coronary heart disease. The system consists of three functional membrane strip pads connected in a sequence for: (from the bottom) immuno-separation based on biotinstreptavidin reaction, catalytic conversion of cholesterol to hydrogen peroxide, and production of a signal. For immuno-chromatography, a monoclonal antibody, specific to apolipoprotein B100 that is present on the surfaces of low-density lipoproteins (LDL) and very low-density lipoproteins (VLDL), with a high binding constant (5×10(10)L/mol) was raised and chemically conjugated to streptavidin. The conjugate was first reacted with lipoprotein particles, and this mixture was absorbed by the capillary action into the biotin pad of the system. After being transferred by medium, immuno-capture of LDL and VLDL particles onto the biotin pad took place, and in situ generation of a signal in proportion to HDL-C consecutively occurred. The capture was selective as well as effective (minimum 90% of LDL and VLDL in clinical concentration ranges), and the detection limit of HDL-C was far lower than 20 mg/dL. To construct a user-friendly device, we are currently investigating the automation of such processes of reactions and separation by adapting a liquid flow-controlling technology that programs the times for the immune reaction and separation. My group further pursues an interdisciplinary study to develop a micro system employing semiconductor-based technologies that will eventually enable the handling of sub-micro liter volume of body fluid as a specimen.

References

Allen MP, DeLizza A, Ramel U, Jeong H, Singh P, Clin. Chem., 36, 1591 (1990)
Artiss JD, Feldbruegge DH, Kroll MH, McQueen MJ, Pry T, Zak B, Ziegenhorn J, Measurement of Cholesterol Concentration, Methods for Clinical Laboratory Measurement of Lipid and Lipoprotein Risk Factors, N. Rifai, and G.R. Warnick (eds.), AACC Press, Washington, DC (1991)
Bachorik PS, Albers JJ, Meth. Enzymol., 129, 78 (1986)
Bachorik PS, Ross JW, Clin. Chem., 41, 1414 (1995)
Contarero LA, Butler JE, Osborne JW, Anal. Biochem., 105, 375 (1980) 
Fisher WR, Schumaker VN, Meth. Enzymol., 128, 247 (1986)
Gordon DJ, Rifkind BM, New Eng. J. Med., 321, 1311 (1989)
Gordon T, Castelli WP, Hjortland MC, Kannel WB, Dawber TR, Amer. J. Med., 62, 707 (1977) 
Gotto J, Antonio M, Pownall HJ, Havel RJ, Meth. Enzymol., 128, 3 (1986)
Hermanson GT, Mallia AK, Smith PK, "Immobilized Affinity Ligand Techniques," Academic Press, Inc., New York (1992)
Hsu SM, Soban E, J. Histochem. Cytochem., 30, 1079 (1982)
Johnson WJ, Mahlberg FH, Rothblat GH, Phillips MC, Biochim. Biophys. Acta, 1085, 273 (1991)
Kohler G, Milstein C, Nature, 256, 495 (1975) 
Law WT, Doshi S, McGeehan J, McGeehan S, Gibboni D, Nikolioukine Y, Keane R, Zheng J, Rao J, Ertingshausen G, Clin. Chem., 43, 384 (1997)
Mackness MI, Durrington PN, "Lipoprotein Separation and Analysis for Clinical Studies, Lipoprotein Analysis," C.A. Converse, and E.R. Skinner (eds.), A Practical Approach, IRL Press, Oxford (1992)
Matson RS, Little MC, J. Chromatogr., 458, 67 (1988) 
Nauck M, Winkler K, Marz W, Wieland H, Clin. Chem., 41, 1761 (1995)
Nilsson S, Lager C, Laurell T, Birnbaum S, Anal. Chem., 67, 3051 (1995) 
Noble D, Anal. Chem., 65, 1037 (1933)
Paek SH, Bachas LG, Schramm W, Anal. Biochem., 210, 145 (1993) 
Paek SH, Jang MR, Mok RS, Kim SC, Kim HB, Biotechnol. Bioeng., 62(2), 145 (1999) 
Rifai N, Warnick GR, McNamara JR, Belcher JD, Grinstead GF, Frantz J, Ivan D, Clin. Chem., 38, 150 (1992)
Rudel LL, Lee JA, Morris MD, Felts JM, Biochem. J., 139, 89 (1974)
Schaefer EJ, "Overview of the Diagnosis and Treatment of Lipid Disorders, Methods for Clinical Laboratory Measurement of Lipid and Lipoprotein Risk Factors," N. Rifai, and G.R. Warnick (eds.), AACC Press, Washington DC (1991)
Schramm W, Paek SH, Anal. Biochem., 205, 47 (1992) 
Skinner ER, "The Separation and Analysis of High-density Lipoprotein (HDL) and Low-density Lipoprotein (LDL) Subfractions, Lipoprotein Analysis," C.A. Converse, and E.R. Skinner (eds.), A Practical Approach, IRL Press, Oxford (1992)
Sterling B, Kiang T, Subramanian K, Saltman M, Smart W, Tsay M, Sugarman J, Patel D, Monger D, Martin D, Gibbons I, Voss F, Clin. Chem., 38, 1658 (1992)
Tall AR, J. Clin. Invest., 86, 379 (1990)
Warnick GR, Wood PD, Clin. Chem., 41, 1427 (1995)
Weber PC, Ohlendorf DH, Wendoloski JJ, Salemme FR, Science, 243, 85 (1989) 

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로