ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received April 17, 2003
Accepted October 10, 2003
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Mass Transfer Studies on Ternary Systems in a Bench-scale Liquid-Liquid Extraction (LLX) Column and a Comparison with Simulations

Department of Chemical Engineering, Indian Institute of Technology Kanpur, Kanpur-208 016 (U.P.), India
akhanna@iitk.ac.in
Korean Journal of Chemical Engineering, March 2004, 21(2), 511-520(10), 10.1007/BF02705442
downloadDownload PDF

Abstract

Mass transfer studies in a laboratory scale extraction column have been conducted for Toluene-Acetone-Water and MIBK-Acetic Acid-Water systems. From these experiments stage-wise solute (Acetone or Acetic-Acid) composition profiles have been obtained for both dispersed and continuous phase. These composition profiles have been compared with those obtained from ASPENPLUS, CHEMSEP and LLXSIM simulators. For liquid-liquid equilibrium calculations all these simulators use UNIFAC and UNIQUAC model. The binary interaction parameters for the UNIFAC are inbuilt in ASPENPLUS and CHEMSEP. UNIQUAC binary parameters were borrowed from DECHEMA. Error square analysis indicates that simulations based on non-equilibrium option of LLXSIM match closely with experimental results. Temperature profiles and hydrodynamic features characterized by number of drops and static holdup on the stages have been compared between the LLXSIM simulated and the experimental results and these match well. However simulations on ASPENPLUS give sum of relative error-squares for all the experimental runs at least ten times higher, in spite of tuning the average stage efficiency.

References

AspenPlus Ver 10.0 developed by Aspen Technology, Inc. Cambridge, Massachusetts, USA
ChemSep Ver 3.71, CACHE Student Edition, developed by Kooijman, H., Haket, A., Taylor, R. (1988)
Chun BS, Lee HG, Cheon JK, Wilkinson G, Korean J. Chem. Eng., 13(3), 234 (1996)
Debjit S, Khanna A, "Rate-Based and Non-Isothermal Aromatic Extraction Column Model," Proc. PETCON 2000, IIT Kharagpur, India, Jul. 1-2, 149
Handlos AE, Baron T, AIChE J., 3, 127 (1957) 
Kehat E, Ghitis B, Comput. Chem. Eng., 5, 171 (1981) 
Macedo EA, Rasmussen P, "Liquid-liquid Equilibrium Data Collection," Supplement 1, Chemistry Data Series, Volume V, Part 4, DECHEMA, 270, 495 (1987)
Sanpui D, Khanna A, Korean J. Chem. Eng., 20(4), 609 (2003)
Siddiqi MA, Lucas K, Can. J. Chem. Eng., 64, 839 (1986)
Skelland AHP, Conger WL, Ind. Eng. Chem. Process Des. Dev., 12, 448 (1973) 
Weidlich U, Gmehling J, Ind. Eng. Chem. Res., 26, 1372 (1987) 
Wesselingh JA, Krishana R, "Mass Transfer," Ellishorwood, Chichester, England (1990)
Zimmermann A, Joulia X, Gourdon G, Gorak A, Chem. Eng. J., 57, 229 (1995)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로