ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received June 1, 2003
Accepted October 1, 2003
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Chiral Separation of Ketoprofen Racemate by using Chirex® 3005 and Kromasil® CHI-II Chiral Column

Department of Chemical Engineering, Chungnam National University, Daejeon 305-764, Korea
ihkim@cnu.ac.kr
Korean Journal of Chemical Engineering, March 2004, 21(2), 521-526(6), 10.1007/BF02705443
downloadDownload PDF

Abstract

Ketoprofen is a non-steroid anti-inflammatory drug (NSAID) that has analgesic, anti-inflammatory and antipyretic properties, of which pharmacological activity has been contributed mainly by the S-ketoprofen enantiomer. To gain highly purified S-ketoprofen enantiomer from ketoprofen racemate, suitable stationary phase was investigated by comparing R-type naphthylglycine and 3,5-dinitrobenzoic acid of Chirex® 3005 and O,O'-bis(4-tertbutyl-benzoyl)-N and N'-diallyl-L-tartardiamide of Kromasil® CHI-II. S-ketoprofen enantiomer was successfully isolated by using the Kromasil column as well as the mobile phase of hexane/tert-butyl methyl ether/acetic acid (v/v)=60/40/0.1. Equilibrium constants of R- and S-ketoprofen were obtained by pulsed injection method (PIM) at various concentrations of ketoprofen racemate and loading sample amounts, which serve the basic information on overloading sample volume and amounts. A volume of 100 μl containing 3.0 mg of ketoprofen racemate to Kromasil column (250 mm×4.6 mm) resulted in 85% recovery of injected sample under an high concentration (30 mg/ml) feed condition.

References

Blanco M, Coello J, Iturriaga H, Maspoch S, Perez-Maseda C, J. Chromatogr. A, 793(1), 165 (1998) 
Boisvert J, Caille G, McGilveray IJ, Qureshi SA, J. Chromatogr. B, 690, 189 (1997)
Gindy AE, Ashour A, Abdel-Fattah L, Shababa MM, J. Pharm. Biomed. Anal., 25(2), 171 (2001) 
Francotte ER, Richert P, J. Chromatogr. A, 769(1), 101 (1997) 
Grubb NG, Rudy DW, Hall SD, J. Chromatogr. B, 678(2), 237 (1996)
Jagota NK, Stewart JT, J. Chromatogr. A, 604(2), 255 (1992) 
Kakodkar SV, Witiak DT, Johnson TP, Baldwin JR, Rahwan RG, J. Medicinal Chem., 22(1), 77 (1979) 
Menzel-Soglowek S, Geisslinger G, Brune K, J. Chromatogr. B, 532, 295 (1990)
Meyring M, Chankvetadze B, Blaschke G, J. Chromatogr. A, 876, 157 (2000) 
Morrison RT, Boyd RN, "Organic Chemistry," 6th ed., 136, Prentice-Hall Inc., New York, U.S.A. (1992)
Oshima T, Inoue K, Furusaki S, Goto M, J. Membr. Sci., 217(1-2), 87 (2003) 
Pietta P, Manera E, Ceva P, J. Chromatogr., 387, 525 (1987) 
Sallustio BC, Abas AP, Hayball J, Purdie YJ, Meffin PJ, J. Chromatogr. B, 374(2), 329 (1986)
Schurig V, Juza M, J. Chromatogr. A, 757, 119 (1997) 
Wainer IW, "Drug Streochemistry: Analytical Method and Pharmacology," 2nd ed., Marcel Dekker, New York, 67 (1993)
Wright MR, Jamali F, J. Chromatogr. B, 616, 59 (1993)
Van Overbeke A, Baeyens W, VanDen Bossche W, Dewaele C, J. Pharm. Biomed. Anal., 12(7), 911 (1994) 

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로