ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2025 KICHE. All rights reserved

Articles & Issues

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received September 26, 2006
Accepted February 6, 2007
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Photobiocatalytic hydrogen production in a photoelectrochemical cell

Greenhouse Gas Research Center, Fossil Energy & Environment Research Department, Korea Institute of Energy Research, 71-2 Jang-dong, Yusong-gu, Daejeon 305-343, Korea
hkjoo@kier.re.kr
Korean Journal of Chemical Engineering, September 2007, 24(5), 742-748(7), 10.1007/s11814-007-0036-4
downloadDownload PDF

Abstract

In this study the photobiocatalytic hydrogen production system was photoelectrochemically examined. Preliminary experiments with a mixed slurry system revealed the following five facts: direct, inter-phase, electron transfer from photocatalyst to enzyme in the absence of electron relay was a rate-determining step; the enzyme was deactivated by irradiated light (half after 10 days); physical properties (crystallinity, specific surface area, pore volume and radius) of the photocatalysts, obtained by two preparation methods (sol-gel and hydrothermal), were seldom correlated with the production rate; chemical properties were postulated to have been affected; and each material needed different reaction conditions such as pH and temperature. For the later salt-bridged system, the I-V relation for each prepared photocatalyst was measured (Vfb in the range of ca. .0.9~.1.0 and Voc close to .1.1 V vs. Ag/AgCl in saturated KCl). The change in the amount of evolved hydrogen was also independently checked according to external bias (critical bias around 1.0 V). Then both reaction components were connected through a salt bridge to initiate light-induced hydrogen production for the hybrid system. The H2 production exhibited an exponential trend and the Tris-HCl buffer showed the highest rate. A feasible reaction pathway was proposed.

References

Raupp GB, Alexiadis A, Hossain MM, Changrani R, Catal. Today, 69(1-4), 41 (2001)
Luzzi A, Final report for IEA Hydrogen Program Annex-14 (2004)
Bak T, Nowotny J, Rekas M, Sorrell CC, Int. J. Hydrog. Energy, 27(1), 19 (2002)
Ashai R, Morikawa T, Ohwaki T, Aoki K, Taga Y, Science, 293, 269 (2001)
Ihara T, Miyoshi M, Iriyama Y, Matsumoto O, Sugihara S, Appl. Catal. B: Environ., 42(4), 403 (2003)
Bryant FO, Adams MWW, J. Biol. Chem., 264(9), 5070 (1989)
Wang W, Varghese OK, Paulose M, Grimes CA, Wang Q, Dickey EC, J. Mater. Res., 19(2), 420 (2004)
Montgomery DC, Design and analysis of experiments, John Wiley & Sons, USA (1991)
Sreethawong T, Suzuki Y, Yoshikawa S, J. Solid State Chem., 178(1), 329 (2005)
Ljubas D, Energy, 30(10), 1699 (2005)
Pedroni P, Mura GM, Galli G, Pratesi C, Serbolisca L, Grandi G, Int. J. Hydrog. Energy, 21(10), 853 (1996)
Larsson M, MS thesis in Lund University, Sweden (2001)
Memming R, Semiconductor electrochemistry, Wiley-VCH, Weinheim, FRG (2001)
He C, Li X, Xiong Y, Zhu X, Liu S, Chemosphere, 58(4), 381 (2005)
Arriaga LG, Fernandez AM, Int. J. Hydrog. Energy, 27(1), 27 (2002)
Butler MA, J. Appl. Phys., 48(5), 1914 (1977)
Gurunathan K, J. Mol. Catal. A-Chem., 156, 59 (2000)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로