articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Influences of humic acids and photoreactivation on the disinfection of Escherichia coli by a high-power pulsed UV irradiation

Department of Environmental Engineering and Biotechnology, Myongji University, Yongin 449-728, Korea 1Green EnTech, Inc., Seoul 153-786, Korea
Korean Journal of Chemical Engineering, September 2009, 26(5), 1301-1307(7), 10.1007/s11814-009-0208-5
downloadDownload PDF

Abstract

The characteristics of inactivation and photoreactivation of Escherichia coli by a high-power pulsed ultraviolet (PUV) irradiation and the influence of the humic acids on disinfection performance were investigated. The pulsed power source was operated at 2,400 V, with 200 J of energy being stored in a 100-μF capacitor. This energy dissipated in the xenon-filled flashlamp within 150 μs, generating a megawatt-level peak power per pulse. The light source was operated at 12 pulses per second (12 Hz). More than a 6-log reduction was achieved via 5 sec of irradiation at a distance of 20 cm, which corresponds approximately to a UV dose of 23 mJ/cm2. The inactivation efficiency decreased with increasing concentrations of humic acids (HA). At the distance of 20 cm, 10 ppm HA reduced the inactivation efficiency to 50%. UV absorption by HA and, in part, the growth-promoting effect of humic acids were implicated in reductions of inactivation performance in the presence of HA. After a disinfection procedure with PUV, the possibility of photoreactivation was greatly reduced and an additional reduction of approximately 1-log was also achieved during 8 h under visible light after inactivation with a UV dosage of 9.0 mJ/cm2 (3 sec at 30 cm). The extent of additional inactivation under visible light was reduced with increasing concentrations of humic acids in water.

References

Stermer RA, Lasater-Smith M, Brasington CF, J. Food Protect., 50, 108 (1987)
Dunn J, Ott T, Clark W, Food Technol., 49, 95 (1995)
USEPA, Ultraviolet disinfection guidance manual, EPA 815-D-03-007 (2003)
Jun S, Irudayaraj J, Demirci A, Geiser D, Int. J. Food Sci. Technol., 38, 883 (2003)
Harm, W, Biological effects of ultraviolet radiation, Cambridge University Press (1980)
Miller R, Jerffrey W, Mitchell D, Elasri M, J. Am. Soc. Microbiol., 65, 535 (1999)
Oguma K, Katayama H, Ohgaki S, Appl. Environ. Microbiol., 68, 6029 (2002)
Sommer R, Cabaj A, Pribil W, Haider T, Wat. Sci. Technol., 35, 113 (1997)
Severin BF, J. Water Poll. Cont. Fed., 52, 2007 (1980)
Lim SJ, Lee YJ, Korean J. Chem. Eng., 23(4), 595 (2006)
Knudson GB, Appl. Environ. Microbiol., 49, 975 (1985)
Harris GD, Adams VD, Sorenson DI, Curtis MS, Water Res., 21, 687 (1987)
Chan YY, Killick EG, Water Res., 29, 1373 (1995)
Tosa K, Hirata T, Water Res., 33, 361 (1999)
Hancock, P, IEEE Trans. Plasma Sci., 32, 2026 (2004)
Bohrerova Z, Shemer H, Lantis R, Impellitteri CA, Linden KG, Water Res., 42, 2975 (2008)
Wang T, MacGregor SJ, Anderson JG, Woolsey GA, Water Res., 39, 2921 (2005)
Chang J, Oddoff SF, Lobe DC, Dorfman MH, Dumais CM, Qualls RG, Johnson JD, Appl. Environ. Microbiol., 49, 1361 (1985)
Otaki M, Okuda A, Tajima K, Iwasaki T, Kinoshita S, Ohgaki S, Water Sci. Technol., 47, 185 (2003)
Craik SA, Weldon D, Finch GR, Bolton JR, Belosevic M, Water Res., 35, 1387 (2001)
Lee SU, Joung M, Yang DJ, Park SH, Huh S, Park WY, Yu JR, Parasitol. Res., 102, 1293 (2008)
Rook JJ, Environ. Sci. Technol., 11, 478 (1977)
Norwood DL, Christman RF, Hatcher PG, Environ. Sci. Technol., 21, 791 (1987)
Reckhow DA, Singer PC, Malcolm RM, Environ. Sci. Technol., 24, 1655 (1990)
Jung CW, Son HJ, Korean J. Chem. Eng., 25(4), 714 (2008)
Corin N, Backlund P, Kulovara M, Chemosphere, 33, 245 (1996)
Yang DJ, The pilot study for the on-site demonstration of the highintensity pulsed UV disinfection system for water treatment, Research Report of The Eco-Technopia 21 Project (061-061-034), The Ministry of Environment, Korea (2008)
Green EnTech, Inc., Pulsed UV disinfection system, http://www.getc.co.kr/Eng/customer/catalogue.htm (2008)
USEPA, Ultraviolet disinfection guidance manual for the final long term 2 enhanced durface water treatment rule, EPA 815-R-06-007 (2006)
Sommer R, Haider T, Cabaj A, Pribil W, Lhotsky M, Water Sci. Technol., 38, 145 (1998)
Clarholm M, Rosswall T, Soil Biol. Biochem., 12, 49 (1980)
Pena-Mendez EM, Havel J, Patocka J, J. Appl. Biomed., 3, 13 (2005)
Kashimada K, Kamiko N, Yamamoto K, Ohgaki S, Water Sci. Technol., 33, 261 (1996)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로