Received November 12, 2010
Accepted January 28, 2011
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Investigation of cleaning solution composed of citric acid and 5-aminotetrazole

Department of Energy and Chemical Engineering, University of Incheon, 12-1 Songdo-dong, Yeonsu-gu, Incheon 406-772, Korea 1LG Display Co., Ltd., 1007, Deogeun-ri, Wollong-myeon, Paju-si, Gyeonggi-do 413-811, Korea 2School of Chemical and Biological Engineering, Seoul National University, 599 Gwanangno, Gwanak-gu, Seoul 151-744, Korea
jjkimm@snu.ac.kr
Korean Journal of Chemical Engineering, July 2011, 28(7), 1619-1624(6), 10.1007/s11814-011-0023-7
downloadDownload PDF

Abstract

In a damascene process for a copper metallization, the planarization method based on a chemical mechanical polishing (CMP) has been used for multilevel metallization. Although a buffing step was adopted in this CMP process, numerous residual abrasives, capable of increasing the resistance of copper lines, still existed after the second CMP step. For this reason, more research has focused on identification of an effective cleaning solution. We investigated a new cleaning solution consisting of citric acid and 5-aminotetrazole (ATRA) as a complexing agent and corrosion inhibitor, respectively. The citric acid was added to achieve a lift-off effect by removing the underlying copper oxide layer, whereas the ATRA was adopted to prevent abrasive re-adsorption by forming a passivation layer on the copper surface. The cleaning solution consisting of 0.006M citric acid and 0.006M ATRA displayed a particle density of 0.07 #/μm2 in an immersion test, and no particles were observed on a 4 cm2 coupon wafer in a real process test at pH 12.

References

Edelstein D, Hedenreich J, Goldblatt R, Cote W, Uzoh C, Lustig N, Roper P, McDevitt T, Motsiff W, Simon A, Dukaic J, Wachnik R, Rathore H, Schulz R, Su L, Luce S, Slattery J, IEEE Interntional Electron Devices Meeting., 773 (1997)
Andricacos PC, Uzoh C, Dukovic JO, Horkans J, Deligianni H, IBM J. Res. Dev., 42, 567 (1998)
Chen KW, Wang YL, Chang L, Chang SC, Li FY, Lin SH, Electrochem. Solid State Lett., 7(10), G238 (2004)
Beverina A, Bernard H, Palleau J, Torres J, Tardif F, Electrochem. Solid State Lett., 3(3), 156 (2000)
Beverina A, Bernard H, Palleau J, Torres J, Tardif F, Electrochem. Solid State Lett., 3(3), 156 (2000)
Paul E, Vacassy R, J. Electrochem. Soc., 150(12), G739 (2003)
Hu CK, Luther B, Kaufman FB, Hummel J, Uzoh C, Pearson DJ, Thin Solid Films, 262(1-2), 84 (1995)
Eom DH, Park JG, Lee ES, Jap. Soc. Appl. Phys., 41, 1305 (2002)
Lee SY, Lee SH, Park JG, J. Electrochem. Soc., 150(5), G327 (2003)
Walker R, Corrosion., 31, 97 (1975)
Mansfeld F, Smith T, Corrosion., 29, 105 (1973)
Cohen SL, Brusic VA, Kaufman FB, Frankel GS, Motakef S, Rush B, J. Vac. Sci. Technol., 8, 2417 (1990)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로