ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received June 10, 2015
Accepted October 11, 2015
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

A numerical study on the performance evaluation of ventilation systems for indoor radon reduction

Department of Environmental Engineering, Yonsei University, Wonju 220-710, Korea
Korean Journal of Chemical Engineering, March 2016, 33(3), 782-794(13), 10.1007/s11814-015-0214-8
downloadDownload PDF

Abstract

Numerical simulations were conducted using computational fluid dynamics to evaluate the effect of ventilation conditions on radon (222Rn) reduction performance in a residential building. The results indicate that at the same ventilation rate, a mechanical ventilation system is more effective in reducing indoor radon than a natural ventilation system. For the same ventilation type, the indoor radon concentration decreases as the ventilation rate increases. When the air change per hour (ACH) was 1, the indoor radon concentration was maintained at less than 100 Bq/m3. However, when the ACH was lowered to 0.01, the average indoor radon concentration in several rooms exceeded 148 Bq/m3. The angle of the inflow air was found to affect the indoor air stream and consequently the distribution of the radon concentration. Even when the ACH was 1, the radon concentrations of some areas were higher than 100 Bq/m3 for inflow air angles of 5o and 175o.

References

World Health Organization, WHO Handbook on Indoor Radon: a Public Health Perspective, WHO Press, France (2009).
Page S, J. Environ. Health, 56, 27 (1993)
International Agency for Research on Cancer, IARC Monographs on the Evaluation of Carcinogenic Risks to Humans: Man-made Mineral Fibres and Radon, IARC Press, U.K. (1988).
International Agency for Research on Cancer, IARC Monographs on the Evaluation of Carcinogenic Risks to Humans: Ionizing Radiation, Part 2: Some Internally Deposited Radionuclides, IARC Press, UK (2001).
Jung SH, Ahn YC, Lee YC, Lee JK, Korean J. Chem. Eng., 30, 2 (2013)
Deng B, Tang S, Kim JT, Kim CN, Korean J. Chem. Eng., 27, 4 (2010)
Fang JB, Persily AK, Computer simulations of airflow and radon transport in four large buildings, National Institute of Standards and Technology (1995).
Zhuo W, Iida T, Moriizumi J, Aoyagi T, Takahashi I, Radiat. Prot. Dosim., 93, 357 (2001)
Wang F, Ward IC, Build. Environ., 35, 615 (2000)
Akbari K, Mahmoudi J, Ghanbari M, J. Environ. Radioact., 116, 166 (2013)
Statistics Korea, 2013 Social Indicators in Korea (2014).
Ministry of Land, Infrastructure and Transport, 2012 Korea Housing Survey (2012).
Ju YJ, The measurement of radon-222 concentration for release gas into the atmosphere from the building material, Master Thesis, Chosun University, Department of Nuclear Engineering (2012).
Min CH, A Study on the trend of interior finishing materials appeared in apartment model house, Master Thesis, Yonsei University, Department of Housing and Interior Design (2003).
Yoo HR, A Survey Study on the Preference of Interior Materials for Multi-Family Housing-Focused on the Medium and Smallsized Apartment in Pangyo newtown in Gyeonggi Province, Master’s Thesis, Seoul National University of Science and Technology, Department of Housing Planning and Design (2006).
American Society of Heating, Refrigerating and Air-Conditioning Engineers, Inc., ANSI/ASHRAE Standard 62.1-2013 Ventilation for Acceptable Indoor Air Quality (2013).
National Legal Information Center, http://www.law.go.kr/main.html.
Korea Meteorological Administration, Annual Climatological Report (2013).
Man CK, Yeung HS, Build. Environ., 32, 351 (1997)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로