ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received September 22, 2015
Accepted December 16, 2015
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Effect of efficient supply of pure O2 concentrated by PSA-type O2 separator on improvement of indoor air quality

Plant Engineering Division, Institute for Advanced Engineering, 175-28, Goan-ro, 51beon-gil, Baekam-myon, Cheoin-gu, Yongin-si, Gyeonggi-do 17180, Korea 1School of Chemical Engineering, Yeungnam University, 214-1 Dae-dong, Gyeongsan, Gyeongbuk 38541, Korea
Korean Journal of Chemical Engineering, April 2016, 33(4), 1305-1310(6), 10.1007/s11814-015-0288-3
downloadDownload PDF

Abstract

To minimize the cost and loss rate of energy artificial room ventilation system, the O2 separator was suggested for the flow of the excessive ventilation amount between indoor and outdoor because the pure O2 separated and concentrated by the O2 separator can be supplied with the ventilation amount minimized. How the O2 separator applies to ventilation and its operation characteristics were investigated by controlling under various conditions as well as the operation conditions optimized required for indoor air quality such as the concentration of CO2 and O2. Consequently, it was known that the O2 concentration was increased; however, the increase of the CO2 concentration was suppressed by the sufficient supply of O2 concentrated from the storage tank into the room despite the two persons’ breathing in the room having an inner volume of about 56m3. Consequently, it was concluded that the supply system of the concentrated O2 which was stored into the tank after the production with the O2 separator can be applied to the room ventilation system for the improvement of the indoor air quality.

References

Ye X, Lian Z, Jiang C, Zhou Z, Chen H, Environ. Monit. Assess, 167, 643 (2010)
Chan LY, Lau WL, Wang XM, Tang JH, Environ. Int., 29, 429 (2003)
Cho JH, Min KH, Paik NW, Int. J. Hyg. Environ. Heal., 209, 249 (2006)
Feng YL, Mu CC, Zhai JQ, Li JA, Zou T, J. Hazard. Mater., 183(1-3), 574 (2010)
Park DU, Ha KC, Environ. Int., 34, 629 (2008)
Martin DS, Grocott III MP. Br J Anaesth, 111, 867 (2013).
Iscoe S, Beasley R, Fisher JA, Crit Care, 15, 305 (2011)
Cornet AD, Kooter AJ, Peters MJ, Smulders YM, Arch. Intern. Med., 172, 289 (2012)
Capellier G, Panwar R, Crit. Care Resusc., 13, 139 (2011)
Budinger GR, Mutlu GM, Chest, 143, 1151 (2013)
Meyhoff CS, Staehr AK, Rasmussen LS, Curr. Opin. Anaesthesiol., 25, 363 (2012)
Metnitz PG, Metnitz B, Moreno RP, Bauer P, Sorbo LD, Hoermann C, De Carvalho SA, Ranieri VM, Intensive Care Medicine, 35, 816 (2009)
Espitalier-Noel PM, Waster recycle pressure swing adsorption to enrich oxygen from air, Ph.D. Thesis, University of Surrey, UK (1988).
Sircar S, in: Rodrigues A, LeVan M, Tondeur D (Eds.), NATO ASI Series,158, 285 (1989).
Lai SM, Lai HY, Chou MY, Microporous Mesoporous Mater., 196, 31 (2014)
Frankowicz M, Chrenowski M, Physica B, 372, 219 (2006)
Lu R, Cao Z, Liu X, J. Natural Gas Chemistry, 17, 142 (2008)
Esparza JM, Ojeda ML, Campero A, Hernandez G, Felipe C, Asomoza M, Cordero S, Kornhauser I, Rojas F, J. Mol. Catal. A-Chem., 228(1-2), 97 (2005)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로