ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received April 13, 2018
Accepted August 5, 2018
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

Nickel nanoparticles-doped rhodamine grafted carbon nanofibers as colorimetric probe: Naked eye detection and highly sensitive measurement of aqueous Cr3+ and Pb2+

School of Chemical Sciences, Central University of Gujrat, Gandhinagar 382030, India 1Center for Environmental Science and Engineering, Indian Institute of Technology Kanpur, Kanpur 208016, India
dinesh.kumar@cug.ac.in
Korean Journal of Chemical Engineering, January 2019, 36(1), 126-135(10), 10.1007/s11814-018-0139-0
downloadDownload PDF

Abstract

Nickel nanoparticle (NiNPs)-doped carbon nanofiber (CNF) grafted with Rhodamine-B (RhB) dye (Ni- CNF-RhB), was prepared and utilized as a colorimetric probe for detection and measurements of chromium (Cr3+) and lead (Pb2+) metal ions in aqueous systems. An intense pink solution was obtained within 30 s on the exposure of the colorless Ni-CNF-RhB probe to the metal ions (Cr3+ and Pb2+) solution. Briefly, the NiNPs-doped carbon beads were synthesized and applied as a substrate to grow CNFs by chemical vapor deposition. The Ni-CNF-RhB colorimetric probe exhibited fast response and selective determination towards Cr3+ and Pb2+ over the 0.1-10 ppm concentration range of their respective solution pH. The developed probe also showed the pH-dependent colorimetric response, thereby, selectivity determination of the metal ions. The detection limits of the colorimetric probe against Cr3+ and Pb2+ are 203 and 132 nM, respectively. The binding ability of the RhB-dye was augmented by CNF and NiNPs, while the carbon beads provided support to CNF to help probe in detection application and its re-usability. The method to prepare the colorimetric probe is simple, novel, selective, and the probe can be efficiently used for the fast detection (naked eye) and measurements of toxic metal ions in aqueous systems.

References

Bontideana I, Mortaria A, Letha S, Brownb NL, Karlsonc U, Larsenc MM, Vangronsveldd J, Corbisiere P, Csoregi E, Environ. Pollut., 131, 255 (2004)
Fu F, Wang Q, J. Environ. Manage., 92(3), 407 (2011)
Kuban P, Guchardi R, Hauser PC, Trends Anal. Chem., 24, 192 (2005)
Kim HN, Ren WX, Kim JS, Yoon Y, Chem. Soc. Rev., 41, 3210 (2012)
Lohani CR, Kim JM, Chung SY, Yoon J, Lee KH, Analyst, 135, 2079 (2010)
Larki A, Spectroc. Acta Pt. A-Molec. Biomolec. Spectr., 173, 1 (2017)
Halder A, Bhattacharya S, Spectroc. Acta Pt. A-Molec. Biomolec. Spectr., 99, 335 (2012)
Tian Z, Cui S, Zheng C, Pu S, Spectroc. Acta Pt. A-Molec. Biomolec. Spectr., 173, 75 (2017)
Li GW, Zhang LH, Li ZW, Zhang WQ, J. Hazard. Mater., 177(1-3), 983 (2010)
Liao VHC, Chien MT, Tseng YY, Ou KL, Environ. Pollut., 142, 17 (2006)
Farhadia K, Forougha M, Molaeia R, Hajizadeha S, Rafipour A, Sens. Actuators B-Chem., 161, 880 (2012)
Saha K, Agasti SS, Kim C, Li XN, Rotello VM, Chem. Rev., 112(5), 2739 (2012)
Chang HY, Hsiung TM, Huang YF, Huang CC, Environ. Sci. Technol., 45, 1534 (2011)
Kaoutit HE, Estevez P, Ibeas S, Garcia F, Serna F, Benabdelouahab FB, Garcia JM, Dyes Pigment., 96, 414 (2103)
Liu A, Yang L, Zhang Z, Zhang Z, Xu D, Dyes Pigment., 99, 472 (2013)
Zhang X, Shiraishi Y, Hirai T, Tetrahedron Lett., 48, 5455 (2007)
Sunnapu O, Kotla NG, Maddiboyina B, Singaravadivel S, Sivaraman G, RSC Adv., 6, 656 (2016)
Tang Z, Ding XL, Liu Y, Zhao ZM, Zhao BX, RSC Adv., 5, 99664 (2015)
Xiao S, Shen M, Guo R, Huang Q, Wang S, Shi X, J. Mater. Chem., 20, 5700 (2010)
Bikshapathi M, Mandal S, Mathur GN, Sharma A, Verma N, Ind. Eng. Chem. Res., 50(23), 13092 (2011)
Sharma A, Verma N, Sharma A, Deva D, Sankararamakrishnan N, Chem. Eng. Sci., 65(11), 3591 (2010)
Saraswat R, Talreja N, Deva D, Sankararamakrishnan N, Sharma A, Verma N, Chem. Eng. J., 197, 250 (2012)
Ahmad A, Kern K, Balasubramanian K, ChemPhysChem., 10, 905 (2009)
Aragay G, Pons J, Merkoc A, J. Mater. Chem., 21, 4326 (2011)
Kumar V, Talreja N, Deva D, Sankararamakrishnan N, Sharma A, Verma N, Desalination, 282, 27 (2011)
Talreja N, Kumar D, Verma N, Clean-Soil, Air, Water, 44, 1 (2016)
Talreja N, Kumar D, Verma N, J. Water Process Eng., 3, 34 (2014)
Khare P, Talreja N, Deva D, Sharma A, Verma N, Chem. Eng. J., 229, 72 (2013)
Zhang R, Hummelga M, Lv G, Olin HK, Carbon, 49, 1126 (2011)
Qiao H, Wei Z, Yang H, Zhu L, Yan X, J. Nanomater, 2009, 795928 (2009)
Kumawat LK, Mergu N, Asif M, Gupta VK, Sens. Actuators B-Chem., 231, 847 (2016)
Zhang H, Liu Q, Wang T, Yun Z, Li G, Liu J, Jiang G, Anal. Chim. Acta, 770, 140 (2013)
Abolhasani J, Hassanzadeh J, Jalali ES, Int. Nano Lett, 4, 65 (2014)
Rajeshwari EM, Chandrasekaran N, Mukherjee A, Anal. Method, 5, 6211 (2013)
Wang X, Wei Y, Wang S, Chen L, Colloids Surf. A: Physicochem. Eng. Asp., 472, 57 (2015)
Ferhan AR, Guo L, Zhou X, Chen P, Hong S, Kim DM, Anal. Chem., 85, 4094 (2013)
Wei H, Li B, Li J, Dong S, Wang E, Nanotechnology, 19(9): 095501 (2008).
Ding N, Cao Q, Zhao H, Yang Y, Zeng L, He Y, Xiang K, Wang G, Sensors, 10, 11144 (2010)
Li T, Wang E, Dong S, Anal. Chem., 82, 1515 (2010)
Kuang H, Xing C, Hao C, Liu L, Wang L, Xu C, Sensors, 13, 4214 (2013)
Beija M, Afonso CAM, Martinho JMG, Chem. Soc. Rev., 38, 2410 (2009)
Sahana A, Banerjee A, Lohar S, Sarkar B, Mukhopadhyay SK, Das D, Inorg. Chem., 52, 3627 (2103)
Kalwar NH, Sirajuddin, Sherazi STH, Khaskheli AR, Hallam KR, Scott TB, Tagar ZA, Hassan SS, Soomro RA, Appl. Catal. A: Gen., 453, 54 (2013)
Kalwar NH, Sirajuddin, Soomro RZ, Hussain STS, Hallam KR, Khaskheli AR, Int. J. Metal., 2014, 1 (2014)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로