articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

OXYGEN TRANSFER ANALYSIS IN A DUAL HOLLOW-FIBER BIOREACTOR SYSTEM

Korean Journal of Chemical Engineering, March 1988, 5(1), 83-85(3), 10.1007/BF02697481
downloadDownload PDF

Abstract

Oxygen transfer analysis in a dual hollow-fiber bioreactor system was carried out by simulation. Oxygen penetration depth and volumetric oxygen uptake rate were not much affected by the silicone membrane thickness and major portion of oxygen transfer resistance existed in the immobilized cell layer.