- This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.
All issues
FAST DETERMINATION OF LANGMUIR ISOTHERM PARAMETERS IN LARGE CONCENTRATION OF ONE SOLUTE
Korean Journal of Chemical Engineering, April 1990, 7(2), 151-153(3), 10.1007/BF02705062
Download PDF
Abstract
A simple method is presented to obtain the Langmuir isotherm parameters. Although this method is limited to the case of large concentration, a few injections enable the determination of the parameters. For a sample of thymine, with the injection volumes of 1.0 and 1.5ml, the parameters of a and b are determined as 15.83 ml/ml and 0.12 ml/mg, respectively.
References
Grushka E, "Preparative-Scale Chromatography," Marcel Dekker, Inc., New York (1989)
Ruthven DM, "Principles of Adsorption and Adsorption Processes," John Wiley & Sons, Inc., New York (1984)
Guiochon G, Ghodbane S, J. Phys. Chem., 92, 3682 (1988)
Ghodbane S, Guiochon G, J. Chromatogr., 450, 27 (1988)
Nogare SD, Juvet RS, "Gas-Liquid Chromatography: Theory and Practice," John Wiley & Sons, Inc., New York (1962)
Ruthven DM, "Principles of Adsorption and Adsorption Processes," John Wiley & Sons, Inc., New York (1984)
Guiochon G, Ghodbane S, J. Phys. Chem., 92, 3682 (1988)
Ghodbane S, Guiochon G, J. Chromatogr., 450, 27 (1988)
Nogare SD, Juvet RS, "Gas-Liquid Chromatography: Theory and Practice," John Wiley & Sons, Inc., New York (1962)