ISSN: 0256-1115 (print version) ISSN: 1975-7220 (electronic version)
Copyright © 2024 KICHE. All rights reserved

Overall

Language
English
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received February 12, 2024
Accepted June 23, 2024
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

Most Cited

Emission Factor Estimation Using Monte Carlo Simulation: Focusing on the Development of Dioxin Emission Factors in Cremation Facilities

University of Seoul , 163 Seoulsiripdaero
catalica@uos.ac.kr
Korean Journal of Chemical Engineering, September 2024, 41(9), 2607-2619(13), https://doi.org/10.1007/s11814-024-00211-4

Abstract

In this study, data from 23 domestic cremation facilities measured for 5 years (from 2016 to 2020) of 13 domestic cremation

facilities was used to calculate the emission factors of dioxins (PCDD/DFs) of cremation facilities that use Liquifi ed Natural

Gas (LNG) as combustion fuel. We performed a statistical analysis for the fi rst time to estimate the emission factor using

limited measurement results from cremation facilities that are not easily accessible. We attempted to identify the emission

concentration of dioxin as a representative persistent organic pollutants substance and developed a statistically based dioxin

emission factor. The concentration of dioxins (PCDD/DFs) in the cremation facility ranged 0.001–4.440 ng I-TEQ/Sm 3

with an average concentration of 0.719 ng I-TEQ/Sm 3 . The emission factor calculated using the 23 measured data showed

0.010–21.485 μg I-TEQ/Cremation. A Monte Carlo Simulation was conducted using probability density distribution and

parameter estimation. Consequently, 10,000 emission factors were selected, and the Pareto distribution was predicted to be

the most appropriate probability density distribution. The emission factor values through Monte Carlo simulation showed

a minimum value of 1.490 × 10–08 μg I-TEQ/Cremation and a maximum value of 7816 μg I-TEQ/Cremation. The average

value was calculated as 39.920 μg I-TEQ/Cremation. Each parameter of the Pareto distribution is shape parameter ( α ) 1.026,

location parameter ( μ ) – 1.021, and scale parameter ( λ ) 1.021. As a result of this study, the median value of the cumulative

density function was selected as a representative value for the dioxin emission factor of cremation facilities and the emission

factor was 0.986 μg I-TEQ/ Cremation. The 95% confi dence interval in the Pareto distribution was presented as 0.026 μg

I-TEQ/Cremation to 36.216 μg I-TEQ/ Cremation.

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
TEL. No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Journal of Chemical Engineering 상단으로