ISSN: 0304-128X ISSN: 2233-9558
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

혈관근육세포내에서의 Na+과 K+이온의 이동현상에 대한 동역학적 해석

Kinetic Analysis of Sodium and Potassium Ion Transfer in the Arterial Smooth Muscle Cells

HWAHAK KONGHAK, February 1982, 20(1), 49-60(12), NONE
downloadDownload PDF

Abstract

혈관근육의 수축과정에 관련된 기구를 알아 보고자 스테인레스강철대에 꿰인 개의 혈관도막을 사용하여 혈관벽내에서의 Na+과 K+이온들의 이동 등 특성을 연구하였다. 세포사이공간내에서의 확산과 능동적 및 피동적 기구에 의한 세포막투과를 함께 고려한 수학적 모형에 의거하여 추적자세척실험데이터를 분석하였으며 그로부터 세포성질에 대한 수치를 얻었다. 세포사이공간내에서의 Na+이온의 확산계수는 37 ℃에서 8.33×10-6 cm2/sec, 21 ℃에서 6.88×10-6 cm2/sec이였고 37 ℃에서 K+이온의 값은 1.23×10-5 cm2/sec이였다. Na+이온의 세포막투과성은 37 ℃ 와 21.2 ℃에서 각각 0.60×10-8 cm/sec, 0.52×10-8 cm/sec이였고 37 ℃에서 K+이온에 대한 값은 3.3×10-8 cm/sec였으며 Na+이온의 능동적 세포막투과속도는 37 ℃와 21.2 ℃에서 각각 2.09×10-9 mEq/cm2sec, 1.52×10-9 mEq/cm2sec였다. K+이온에 대해서는 37 ℃에서 0.82×10-9 mEq/cm2sec의 값을 얻었다. 또한 37 ℃에서 Na+이온과 K+이온의 세포내 농도는 각각 18.7, 126 mEq/l이였고 21.2 ℃에서 Na+이온의 값은 27.5 mEq/l였다. 이러한 결과는 Na+ - K+펌프는 연결비가 2 : 1로서 기전적임을 시사하고 있으며 나아가 기전적 Na+ - K+ 펌프가 세포막전압을 유지하고 혈액흐름에 대한 혈관저항을 조절함에 있어 주요한 역할을 한다는 가정과 일치한다.
In an attempt to help elucidate the mechanisms involved in the contractile processes of vascular smooth muscle, the transport kinetics of Na+ and K+ in arterial walls (branches of canine femoral artery) were studied with isolated sections of vessels mounted on stainless steel rods. The experimental tracer washout data were analyzed based on a mathematical model, which takes into account diffusion in the extracellular space and transport across the cell membranes by both passive and active mechanisms, yielding values for the membrane properties. Values were obtained for the diffusion coefficient of the ions in the extracellular space (8.33×10-6 cm2/sec at 37 ℃ and 6.88×10-6 at 21.2 ℃ for Na+ and 1.23×10-5 at 37 ℃ for K+), the membrane permeabilities to the ions (0.60×10-8 cm/sec at 37 ℃ and 0.52×10-8 at 21.2 ℃ for Na+ and 3.3×10-8 at 37 ℃ and K+), the rate of active transport of ions through the cell membranes (2.09×10-9 mEq/cm2sec at 37 ℃ and 1.52×10-9 at 21.2 ℃ for Na+ and 0.82×10-9 at 37 ℃ for K+), and the intracellular ion concentrations (18.7 mEq/l at 37 ℃ and 27.5 at 21.2 ℃ for Na+ and 126 at 37 ℃ for K+). The results indicate that the Na+ - K+ pump is electrogenic with a coupling ratio in the order of 2 to 1. This is consistent with the hypothesis that an electrogenic Na+ - K+ pump plays a role in maintaining the cell potential and in regulation of vascular resistance to blood flow.

Keywords

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Chemical Engineering Research 상단으로