Articles & Issues
- Conflict of Interest
- In relation to this article, we declare that there is no conflict of interest.
- This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.
All issues
무연탄 유동층 연소로의 동특성 연구
A Dynamic Study on an Anthracite Burning Fluidized Bed
HWAHAK KONGHAK, August 1982, 20(4), 283-292(10), NONE
Download PDF
Abstract
본 연구는 유동층 연소로에서 고체입자의 홉합특성과 연소특성을 고찰하고 이와 관련하여 저질 무연탄의 유동층내에서 연소 가능성을 타진하기 위한 것이다.
연소영역이 층상부에 형성된다고 하여 고체입자의 혼합모델을 제시하고 이를 실험치와 비교하였다.
고체입자의 혼합은 고온 연소로에서 그리고 상온유동층에서 충격응답법에 의하여 고찰하였으며, 연소영역의 존재는 고온 회분 유동층에 일정량의 석탄입자를 주입한 후의 층내 온도변화를 해석함으로서 확인하였다.
유동층 연소로에서 고체혼합에 관한 실험결과는 상온유동층과 매우 틀리며, 이는 연소되는 입자들이 층상부로 분리되어 연소영역을 형성하는 것으로 설명할 수 있었다. 제시된 모델은 실험치와 잘 일치하며 본 연구를 통하여 저질 무연탄의 연소시 다음과 같은 조업조건을 제시할 수 있다. 즉 층 높이와 직경의 비는 1.5 이하, 층내 온도는 900 ℃ 부근이 좋으며, 석탄시료의 주입은 상부, 회분의 배출은 하부에서 하여야 한다.
연소영역이 층상부에 형성된다고 하여 고체입자의 혼합모델을 제시하고 이를 실험치와 비교하였다.
고체입자의 혼합은 고온 연소로에서 그리고 상온유동층에서 충격응답법에 의하여 고찰하였으며, 연소영역의 존재는 고온 회분 유동층에 일정량의 석탄입자를 주입한 후의 층내 온도변화를 해석함으로서 확인하였다.
유동층 연소로에서 고체혼합에 관한 실험결과는 상온유동층과 매우 틀리며, 이는 연소되는 입자들이 층상부로 분리되어 연소영역을 형성하는 것으로 설명할 수 있었다. 제시된 모델은 실험치와 잘 일치하며 본 연구를 통하여 저질 무연탄의 연소시 다음과 같은 조업조건을 제시할 수 있다. 즉 층 높이와 직경의 비는 1.5 이하, 층내 온도는 900 ℃ 부근이 좋으며, 석탄시료의 주입은 상부, 회분의 배출은 하부에서 하여야 한다.
The mixig characteristics of the particles, the combustion behavior and the combustibility of low grade anthracite coal in the fluidized bed were determined.
A model, which assumed the main combustion zone located at the upper part of the bed, was proposed and compared with experiments. The mixing of the particles was experimentally studied by employing an impulse tracer technique both for hot combusting bed and for cold bed. Also, the combustion zone was experimentally confirmed by analyzing the temperature changes in the bed after injecting a small amount coal particles to the hot ash fluidized bed.
The experimental results on the mixing in the combusting bed were considerably different from those in the cold bed and that could be interpreted by assuming the upward stratification of burning coal particles. Through this investigation, it could be concluded that the proposed model agreed well with the experiments and that the recommendable operation conditions for combusting the low grade anthracite in the fluidized bed would be, the aspect ratio, lower than 1.5; the temperature of combustor, about 900 ℃; feeding of the coal, at the top of bed; and discharging at the bottom of the bed.
A model, which assumed the main combustion zone located at the upper part of the bed, was proposed and compared with experiments. The mixing of the particles was experimentally studied by employing an impulse tracer technique both for hot combusting bed and for cold bed. Also, the combustion zone was experimentally confirmed by analyzing the temperature changes in the bed after injecting a small amount coal particles to the hot ash fluidized bed.
The experimental results on the mixing in the combusting bed were considerably different from those in the cold bed and that could be interpreted by assuming the upward stratification of burning coal particles. Through this investigation, it could be concluded that the proposed model agreed well with the experiments and that the recommendable operation conditions for combusting the low grade anthracite in the fluidized bed would be, the aspect ratio, lower than 1.5; the temperature of combustor, about 900 ℃; feeding of the coal, at the top of bed; and discharging at the bottom of the bed.