- This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.
All issues
저질탄 회재와 모래입자의 최소 유동화 속도
Minimum Fluidization Velocity of Low-grade Anthracite Ash and Sand Particles
HWAHAK KONGHAK, February 1987, 25(1), 55-69(15), NONE
Download PDF
Abstract
내경이 7.62×10-2m인 유동층을 사용하여 저질탄 회재 및 모래입자에 대해 최소 유동화 속도를 측정하였다.
실험온도 범위는 15-700℃이고, 입자의 크기는 0.21-2.38mm사이의 3개의 좁은 범위와 저질탄의 유동층 연소에서 층내에 존재할 수 있는 4.76mm이하 및 0.59mm이하인 2개의 광범위한 입자범위를 선택하였다. 작은 입자의 최소 유동화 속도는 온도가 증가함에 따라 감소하고 큰 입자(2mm이상)의 경우는 온도가 증가함에 따라서 최소 유동화 속도가 증가하는 것이 확인되었다. 따라서 실험에서 구한 최소 유동화 속도의 측정값과 기존식으로 부터 구한 계산치를 비교할 때 근본적인 차이가 있었다. 따라서 기존식들보다 저질탄 회재의 최소 유동화 속도를 잘 나타내고 있는 변형된 Ergun식을 제시하였다.
실험온도 범위는 15-700℃이고, 입자의 크기는 0.21-2.38mm사이의 3개의 좁은 범위와 저질탄의 유동층 연소에서 층내에 존재할 수 있는 4.76mm이하 및 0.59mm이하인 2개의 광범위한 입자범위를 선택하였다. 작은 입자의 최소 유동화 속도는 온도가 증가함에 따라 감소하고 큰 입자(2mm이상)의 경우는 온도가 증가함에 따라서 최소 유동화 속도가 증가하는 것이 확인되었다. 따라서 실험에서 구한 최소 유동화 속도의 측정값과 기존식으로 부터 구한 계산치를 비교할 때 근본적인 차이가 있었다. 따라서 기존식들보다 저질탄 회재의 최소 유동화 속도를 잘 나타내고 있는 변형된 Ergun식을 제시하였다.
Minimum fluidization velocity(Umf)of low-grade anthracite ash and sand particles were measured at temperatures ranging from 15 to 700℃ in a fluidized bed of 7.62×10-2m ID.
Two different series of particle size were used : three narrowly sized cut ranging from 0.21 to 2.38 mm, and two of wide size distribution. It was confirmed that Umf for small particles decreases with the increase of temperature but Umf of large particles(>2mm) increases with temperature. However, experimental values of Umf for low-grade anthcite ash differed significantly from those of calculated from existing correlations in the literature. Therefore a modified Ergun equation which gives much better correlation is suggested here.
Two different series of particle size were used : three narrowly sized cut ranging from 0.21 to 2.38 mm, and two of wide size distribution. It was confirmed that Umf for small particles decreases with the increase of temperature but Umf of large particles(>2mm) increases with temperature. However, experimental values of Umf for low-grade anthcite ash differed significantly from those of calculated from existing correlations in the literature. Therefore a modified Ergun equation which gives much better correlation is suggested here.