- This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.
All issues
액체 유동층의 열전달 특성
Heat Transfer Characteristics in Liquid-Fluidized Beds
HWAHAK KONGHAK, February 1987, 25(1), 81-89(9), NONE
Download PDF
Abstract
액체 유동층과 수직 내부 열원간의 열전달현상을 2-저항 모델을 사용하여 해석하였다.
액체의 유속 및 유동입자의 크기가 열원 영역과 유동층 영역의 개별 열전달 저항에 미치는 영향을 규명하였는데, 열원 주위의 경계층의 두께가 최소가 되는 때는 층공극율과 총괄 열전달 계수가 최대값을 나타내는 때의 층공극율이 일치하였다.
액체 유동층에서의 열전달은 열원 영역의 열전달이 율속 단계임이 밝혀졌으며, 총괄 열전달 저항 및 열원영역과 유동층 영역의 개별 저항들을 각각 무차원 수로 나타내어 이들 개별저항들이 series로 연결되어 총괄 열전달 저항을 나타냄을 보였다.
액체의 유속 및 유동입자의 크기가 열원 영역과 유동층 영역의 개별 열전달 저항에 미치는 영향을 규명하였는데, 열원 주위의 경계층의 두께가 최소가 되는 때는 층공극율과 총괄 열전달 계수가 최대값을 나타내는 때의 층공극율이 일치하였다.
액체 유동층에서의 열전달은 열원 영역의 열전달이 율속 단계임이 밝혀졌으며, 총괄 열전달 저항 및 열원영역과 유동층 영역의 개별 저항들을 각각 무차원 수로 나타내어 이들 개별저항들이 series로 연결되어 총괄 열전달 저항을 나타냄을 보였다.
Effects of liquid velocity and particle size on the individual heat transfer resistances in the heater and fluidized bulk zone have been determined.
A two-resistance model is proposed for heat transfer between a coaxially mounted immersed heater and the bulk zone in liquid-fluidized beds. The optimum bed porosity at which the maximum heat transfer coefficient occured coincides with the bed porosity at which the boundary layer thickness around the heater attained the minimum value.
The heat transfer in the heater zone was found to be the rate controlling step in the liquid-fluidized bed and the overall heat transfer resistance has been represented by a modified Stanton and Peclet numbers based on the heat transfer resistances in the heater zone and in the fluidized bulk zone in series.
A two-resistance model is proposed for heat transfer between a coaxially mounted immersed heater and the bulk zone in liquid-fluidized beds. The optimum bed porosity at which the maximum heat transfer coefficient occured coincides with the bed porosity at which the boundary layer thickness around the heater attained the minimum value.
The heat transfer in the heater zone was found to be the rate controlling step in the liquid-fluidized bed and the overall heat transfer resistance has been represented by a modified Stanton and Peclet numbers based on the heat transfer resistances in the heater zone and in the fluidized bulk zone in series.