articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

시멘트 공장의 부유원석분 예열장치와 유동화 하소로의 모델링에 관한 연구

Modeling of a Combined Suspension Preheater and the Fluidized Calciner of a Cement Plant

HWAHAK KONGHAK, August 1987, 25(4), 355-366(12), NONE
downloadDownload PDF

Abstract

시멘트 제조용 원석 분말의 예열은 회전로로부터의 열가스를 다단 사이클론 예열기 내에서 열교환시킴으로서 크게 개선된다. 근자에는 유동화 하소로 등의 새로운 열원을 예열기 계통 내에 병합 가동시킴으로서 하소반응의 반 이상을 예열기 내에서 이루어지게 하여 회전로의 열부하를 감소시키는 효과를 얻게 되었다. 본 연구에서는 22종의 프로그램 변수를 포함한 51개의 입력변수를 선정하고 계의 각 구성요소에 대한 정상가동상태에 있어서의 물질 및 에너지 수지식을 세워 전산모사를 실시하였다. 이와 함께 원석송입속도, 유동화 하소로로의 석탄공급속도, 사이클론의 집진효율, 열손실 및 미분진 재순환속도 등의 변수를 각각 변화시켜 그것이 예열기의 거동에 미치는 영향을 알아보았다. 그 결과 계산으로 예측되는 계의 거동이 실제의 공장조업상의 경향과 일치됨을 알았고, 따라서 이로부터 더 나은 에너지 효율로 운전하는데 대한 지침을 찾을 수가 있었다.
The preheating of cement raw meals is drastically improved by suspending them with the hot kiln gas in a multistage cyclone preheater. Furthermore, the heat load of a rotary kiln is cut down to such an extent that more than a half of the calcination is achieved in the preheater by employing a newly devised equipment, known as the Mitsubishi fluidized calciner, which works as a part of the preheater proper. In this work a total of 51 input parameters including 22 program variables are scrupulously chosen to describe the system by setting up complete material and energy balance equations for each system component in operation under steady state conditions. Five important variables, such as raw meal feed rate, coal feed rate to the fluidized calciner, cyclone efficiencies, radiation losses, and dust circulation rate from the riser duct are chosen to check the impacts of their variations upon the preheater performance. It is found that the calculated results explain reasonably well of the actually observed preheater behaviors. It is also possible that the predicted results can be used as the guide for more energy efficient preheater operations.