articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

소화 하수슬러지의 유동층 소각(I)-단단 유동층 소각특성-

Fluidized Bed Incineration of Digested Sewage Sludge-Part 1. combustion Characteristics of the Single-Stage Fluidized Bed Incinerator

HWAHAK KONGHAK, April 1992, 30(2), 228-236(9), NONE
downloadDownload PDF

Abstract

실험실 규모의 유동층 소각로에서 자연 건조시킨 소화 하수슬러지의 유동층 소각특성을 파악하였다. 실험에 사용한 하수슬러지는 수분함량이 21%dlau 1050kcal/kg 정도의 낮은 발열량을 가지고 있음에도 불구하고 보조연료와 별도의 층매질을 공급함이 없이 정상상태에서 연속적인 조업이 가능하였다. Freeboard 내에서 하수슬러지의 높은 연소율에 의해 연소효율은 94% 이상이었으며, 배출가스 중의 NOx 와 SO2 의 농도는 본 실험조건에서 각각 6.1-16.2ppm, 830-1310ppm이었다.
Combustion characteristics of digested sewage sludges dried in ambient condition were measured in a laboratory scale fluidized bed incinerator. In spite of the low heating value(1050kcal/kg) and the high moisture content(21%) of the sludge, steady state combustion could be obtained without addition of an aux-iliary fuel. Addition of bed material was not needed in the experiment. The combustion efficiency was achieved over 94% due to the high combustion rate of the sludge in the freeboard. Emissions of NOx and SO2 ranged 6.1-16.2ppm and 830-1310ppm, respectively, in given experimental conditions.

Keywords

References

Azuma K, J. Environ. Pollut. Contr., 21(9), 838 (1985)
Environment Administration: Korea Environmental Yearbook(Korea), 880 (1988)
Kawaguchi M, J. Environ. Pollut. Contr. Jpn., 21, 853 (1985)
Baeyens J, Geldart D, Proc. of the Second Eng. Found. Conf., Cambridge, England, 264 (1978)
Wilson EM, Freeman HM, Environ. Sci. Technol., 10, 430 (1976) 
U.S. EPA: EPA/625/4-85/015 (1985)
Liao PB, J. WPCF, 46(8), 1985 (1974)
Kitami S, J. Environ. Pollut. Contr. Jpn., 21(9), 845 (1985)
Takeuchi T, J. Environ. Pollut. Contr. Jpn., 22, 231 (1986)
Lee JK, Hu CG, No JG, Shin YS, Chun HS, HWAHAK KONGHAK, 26(5), 517 (1988)
Lee JK, Hu CG, Shin YS, Chun HS, Proc. of the 10th Int. Conf. on FBC, ASME, San Francisco, U.S.A., Vol. 2, 1190 (1989)
Lee JK, Hu CG, Shin YS, Chun HS, Can. J. Chem. Eng., 68, 824 (1990)
Lee JK, Lee KH, Lee KH, Chun HS, HWAHAK KONGHAK, 28(4), 470 (1990)
Lee JK, Lee KH, Shin YS, Chun HS, Proc. of 11th Int. Conf. on FBC, ASME, Montreal, Canada, Vol. 2, 571 (1991)
Tomita M, Hirama T, Adachi T, Yamaguchi H, ISSNO385-194X, Coal Mining Research Center, Hokkaido, Japan, 88 (1984)
Jixiang L, Proc. of the 9th Int. Conf. on FBC, 1096 (1987)
U.S. EPA: EPA/625/6-85/010 (1985)
U.S. EPA: EPA/625-1-79-011 (1979)
Petho A, Noble RD, RTD Theory in Chem. Eng., Verlag-Chem. GmbH, Weinheim, Germany (1982)
Gong JH, Lim JH, Shin YS, Lee JK, Chun HS, Proc. of the 1st Asian Conf. on Fluidized Bed and 3-Phase Reactors, Tokyo, Japan, 202 (1989)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.