articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

삼상 순환 유동층 생물반응기에서 열전달 계수

Heat Transfer Coefficient in a Three-Phase Circulating Fluidized-Bed Bioreactor

충남대학교 화학공학과, 대전 305-764 1한국원자력연구소 핵화공연구팀, 대전 305-353 2한국과학기술원 화학공학과, 대전 305-701
Department of Chemical Engineering, Chungnam National University, Daejeon 305-764, Korea 1Nuclear Chemical Research Team, Korea Atomic Energy Research Institute, Daejeon 305-353, Korea 2Department of Chemical Engineering, Korea Advanced Institute of Science and Technology, Daejeon 305-701, Korea
HWAHAK KONGHAK, October 2002, 40(5), 640-645(6), NONE
downloadDownload PDF

Abstract

직경이 0.102 m이고 높이가 1.0 m인 기체-액체 순환 및 삼상 순환유동층 생물반응기의 상승관에서 열전달 특성을 고찰하였다. 기체 및 액체의 유속 그리고 생물막 담체의 체류량이 상승관 내부의 수직 열원과 반응기 사이의 열전달 계수에 미치는 영향을 결정하였다. 기체-액체 순환 반응기에서 열전달 계수는 기체의 유속이 증가함에 따라 증가하였으나 액체 유속의 증가에 따라서는 약간 증가하였다. 삼상 순환유동층 생물반응기에서 열전달 계수는 기체의 유속과 유동 생물막 매체의 체류량이 증가함에 따라 증가하였으나 액체의 유속이 증가함에 따라서는 약간 증가하였다. 본 연구의 실험 범위에서 이들 열전달 계수는 실험 조작 변수의 상관식으로 잘 나타낼 수 있었다.
Heat transfer characteristics have been investigated in the riser of gas-liquid circulation and three-phase circulating fluidized-bed bioreactors whose diameter and height are 0.102 m and 1.0 m, respectively. Effects of gas and liquid velocities and holdup of fluidized biofilm media on the heat transfer coefficient between the immersed vertical heater and the bed have been determined. The heat transfer coefficient in the gas-liquid circulation reactor increases with increasing gas velocity, but increases only slightly with increasing liquid velocity. The h(heat transfer coefficient) value in the three-phase circulating fluidized-bed bioreactor also increases with increasing gas velocity or holdup of fluidized biofilm media, but it increases only slightly with liquid velocity. The value of heat transfer coefficient has been well correlated in terms of operating variables.

References

Yu JA, Ji M, Yue PL, J. Chem. Technol. Biotechnol., 74(7), 619 (1999) 
Chang HT, Rittmann BE, Amar D, Heim R, Ehlinger O, Lesty Y, Biotechnol. Bioeng., 38, 499 (1991) 
Kang Y, Fan LT, Min BT, Kim SD, Biotechnol. Bioeng., 37, 580 (1991) 
Converti A, Borghi MD, Ferraiolo G, Can. J. Chem. Eng., 52, 1321 (1993)
Yu H, Rittman B, Water Res., 31, 2604 (1997) 
Liang W, Wu Q, Yu Z, Jin Y, Wang Z, Can. J. Chem. Eng., 73(5), 656 (1995)
Yang WG, Wang JF, Zhou LM, Jin Y, Chem. Eng. Sci., 54(22), 5523 (1999) 
Hamoudi S, Belkacemi K, Sayari A, Larachi F, Chem. Eng. Sci., 56(4), 1275 (2001) 
Cho YJ, Song PS, Kim SH, Kang Y, Kim SD, J. Chem. Eng. Jpn., 34(2), 254 (2001) 
Kang Y, Song PS, Woo KJ, Jeong YY, Kim SD, HWAHAK KONGHAK, 35(6), 819 (1997)
Kang Y, Fan LT, Kim SD, AIChE J., 37, 1101 (1991) 
Kim SD, Kang Y, Chem. Eng. Sci., 52(21-22), 3639 (1997) 
Cho YJ, Park HY, Kim SW, Kang Y, Kim SD, Ind. Eng. Chem. Res., in press (2002)
Park HY, Kim SW, Cho YJ, Kang Y, Kim SD, HWAHAK KONGHAK, 39(5), 619 (2001)
Kim SD, Kang Y, Mixed Flow Hydrodynamics, Advances in Engineering Fluid Mechanics, Gulf Pub. Co., New York, U.S.A. (1996)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Chemical Engineering Research 상단으로