ISSN: 0304-128X ISSN: 2233-9558
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
korean
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received February 18, 2005
Accepted April 23, 2005
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

상용 순환 유동층 연소로 수관벽 전열관 마모속도

Tube Erosion Rate of Water Wall in a Commercial Circulating Fluidized Bed Combustor

건국대학교 화학공학과, 차세대환경기술센타, 143-701 서울시 광진구 화양동 1 1한국에너지기술연구원, 305-343 대전시 유성구 장동 71-2 2수원대학교 환경공학과, 445-743 경기도 화성시 봉당읍 와우리 산2-2 3SKC(주), 680-160 울산시 남구 황성동 600 4한국과학기술원 생명화학공학과, 305-701 대전시 유성구 구성동 373-1
Department of Chemical Engineering, Innovative Environmental Technology Center, Konkuk University, 1, Hwayang-dong, Gwangjin-gu, Seoul 143-701 1Korea Institute of Energy Research, 71-2, Jang-dong, Yuseong-gu, Daejeon 305-343, Korea 2Department of Environmental Engineering, Suwon University, San 2-2, Wau-ri, Bongdam-eup, Hwaseong-si, Gyeonggi-do, 445-743, Korea 3SK Chemical Co., 600, Hwangsung-dong, Nam-gu, Ulsan, 680-160, Korea 4Department of Molecular Biology and Chemical Engineering, KAIST, 373-1, Guseong-dong, Yuseong-gu, Daejeon 305-701, Korea
choijhoo@konkuk.ac.kr
Korean Chemical Engineering Research, August 2005, 43(4), 525-530(6), NONE Epub 27 September 2005
downloadDownload PDF

Abstract

상용 순환 유동층 연소로(200 ton steam/hr, 4.97X9.90X28.98 m)의 수관벽에서 전열관의 마모속도를 측정 및 고찰하였다. 전열관의 두께는 초음파 측정방법을 이용하여 측정되었다. Splash 영역에서 윙월을 포함한 모든 수관벽 전열관의 마모속도가 두드러졌다. 전열관의 마모속도는 분배기로부터 높이가 증가함에 따라서 감소한 후 다시 증가하였다. 프리보드 기체출구 부근의 윙월에서는 기체 및 고체흐름의 편향성으로 인한 마모속도의 차이도 나타났다. 윙월의 마모속도는 연소로 단면의 중앙에 위치할수록 크게 나타났다.
The erosion rate of water wall tube has been measured and discussed in a commercial circulating fluidized bed combustor (200 ton steam/hr, 4.97 × 9.90 × 28.98 m height). Tube thickness was measured with ultrasonic method. Severe tube erosion rate was observed in the splash region on all waterwalls including wingwalls. The tube erosion rate increased after an initial decrease as height from the distributor increased. The difference of erosion rate among wing walls was found due to unbalanced distribution of gas and solid flow rates. The erosion rate of the wing wall increased as location of the wing wall became closer to the center of combustor crosssection.

References

Stringer J, Stallings J, "Material Issues in Circulating Fluidized-Bed Combustors", Proc. of the 11th Int. Conf. on Fluidized Bed Combustion, 589-608 (1991)
Seitzinger DL, "Atmospheric Fluidized Bed Combustion Gas Erosion Solution", Proc. of the 13th Int. Conf. on Fluidized Bed Combustion, 585-595 (1995)
Zhao C, Chang Z, Jin H, Zhang L, "Effects of Fluidization Mode Transition on Erosion of Immersed Tubes in Pressureized Fluidized Bed", Proc. of the 16th Int. Conf. on Fluidized Bed Combustion, FBC01-0181 (2001)
Rogers WA, Boyle EJ, "Wtaer Pediction in a Fludized Bed Combustor", Proc. of the 1993 Int. Conf. on Fluidized Bed Combustion, 811-817 (1993)
Lindsley BA, Marder AR, Lewnard JJ, "The Effect of FBC particle Characteristics on Erosion of a Low Alloy Steel", Proc. of the 1993 Int. Conf. on Fluidized Bed Combustion, 803-809 (1993)
Ninham AJ, Entwisle MJ, Hutchings IM, Little JA, "A Laboratory-Scale Fluidized Bed Rig for High Temperature Tube Wastage Studies", Proc. of Int. Conf. on Fluidized Bed Combustion, 583-589 (1989)
Hou PY, Sum JT, Niu Y, Stringer J, "HCI Effect on In Bed Tube Wastage in Bubbling Flluidized Bed, a Laboratory Study under Simulated Dense Particle Impact Conditions", Proc. of the 15th Int. Conf. on Fluidized Bed Combustion, FBC 99-0137 (1999)
Sethi VK, Barber SA, Sherman SK, Gonzalez RA, Puentes E, Stencel JM, "Wear-Corrosion Synergism in Chlorine-Containing Coal Combustion Environments', Proc. of the 10th Int. Conf. on Fluidized Bed Combustion, 563-574 (1989)
Yamamoto K, Kajigaya I, Sonoya K, Tsuji Y, "material Selection for the Super-Heater and Re-Heater Tubes on PFBC, Based on the Results of Laboratory Test and Ex-Serviced Materials Survey", Proc. of the 16th Int. Conf. on Fluidized Bed Combustion, FBC01-0191 (2001)
Vincent RQ, Canonico DA, Wheeldon JM, "An Evaluation Program for metal Wastage in Fludized Bed Combustors", Proc. of the 1989 Int. Conf. on Fluidized Bed Combustion, 927-935 (1989)
Holtzer GJ, Rademakers PLF, "Studies on 90 MWth AKZO and 4 MWth TNO FBS show Excellent Erosion-Corrosion Results", Proc. of the 1991 Int. Conf. on Fluidized Bed Combustion, 743-753 (1991)
Han KH, "Erosion Characteristics of In-Bed Tubes in Bubling Fluidized Bed Cold Mode Reactor", Master Dissertation, Chungnam National University, Korea (1995)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.