ISSN: 0304-128X ISSN: 2233-9558
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
korean
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received June 20, 2003
Accepted September 8, 2005
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

주조된 매크로 다공성 Poly(glycidyl methacrylate-co-ethylene glycol dimethacrylate) 막대를 이용한 카페인과 트립토판의 분리

Separation of Caffeine and Tryptophan Using Molded Macroporous Poly(glycidyl methacrylate-co-ethylene glycol dimethacrylate) Rods

인하대학교 화학공학과, 초정밀생물분리기술연구센터, 402-751 인천시 남구 용현동 253
Center for Advanced Bioseperation Technology and Department of Chemical Engineering, Inha University, 253, Younghyun-dong, Nam-gu, Incheon 402-751, Korea
rowkho@inha.ac.kr
Korean Chemical Engineering Research, October 2005, 43(5), 603-608(6), NONE Epub 2 November 2005
downloadDownload PDF

Abstract

주조된 매크로 다공성 poly(glycidyl methacrylate-co-ethylene glycol dimethacrylate) 막대를 간단한 주형 과정을 거쳐서 실험실 내 튜브모양의 주형인 크로마토그래피 칼럼(4.6×100 mm)을 사용하여 자유 라디칼 중합에 의해 만들었다. 이는 에폭시 그룹이 유도된 일체형 칼럼과 황산을 이용한 에폭시드 그룹의 화학적인 변형과정을 이용하였다. 단량체 및 포로겐(세공을 생성하는 물질)의 비율, 온도 등 중합반응의 조건을 변화시켜서 세공크기를 조절하여 물질의 체류시 간에 영향을 미쳤다. 본 연구에서는 주조된 일체형 칼럼을 이용하여 카페인과 트립토판을 분리하였으며, 중합원료조성 이 일체형 칼럼의 효율과 선택도 그리고 분리도에 미치는 영향을 고찰하였다.
The molded macroporous poly (glycidyl methacrylate-co-ethylene glycol dimethacrylate) rods produced by a facile molding process were polymerized in situ within a tubular mold, chromatographic column (4.6×100 mm) by free radical polymerization. It was complemented by epoxy derivatized monolithic column and chemical modification of the epoxide groups with the sulphuric acid. By variation of the polymerization conditions, such as the ratio of the monomers, the porogen (pore generating material), and the temperature, the pore size could be varied, so the retention time of the samples may be adjusted. For the mixture of caffeine and tryptophan in the prepared monolithic column, the influences of polymerization material compositions to the efficiency, selectivity, and resolution of the monolithic column were investigated.

References

Svec F, J. Sep. Sci., 27(10), 747 (2004) 
Unger KK, Packings and Stationary Phases in Chromatographic Techniques, M. Dekker, NY, USA (1990)
Svec F, Tennikova TB, Deyl Z, "Monolithic Materials: Preparation, Properties, and Applications", Elsevier, Amsterdam, 173 (2003)
Krajnc P, Leber N, Stefanec D, Kontrec S, Podgornik A, J. Chromatogr. A, 1065(1), 69 (2005) 
Ikegami T, Tanaka N, Curr. Opin. Chem. Biol., 8(1), 1 (2004) 
Strancar A, Podgornik A, Barut M, Necina R, in: R. Freitag (Ed.), Advances in Biochemical Engineering/Biotechnology (Modern Advances Chromatography), vol. 76, Springer, Heidelberg, 49 (2002)
Azanova VV, Hradil J, Svec F, Pelzbauer Z, Panarin EF, React. Polym., 12(3), 247 (1990) 
Azanova VV, Hradil J, Sytov GP, Panarin EF, Svec F, React. Funct. Polym., 16(1), 1 (1991)
Hradil J, Svec F, React. Funct. Polym., 13(1), 43 (1998)
Luo Q, Zou H, Xiao X, Guo Z, Kong L, Mao X, J. Chromatogr. A, 926(2), 255 (2001) 
Gong B, Ke C, Geng X, Chinese J. Chem., 22(3), 283 (2004)
Calleri E, Massolini G, Lubda D, Temporini C, Loiodice F, Caccialanza G, J. Chromatogr. A, 1031(1), 93 (2004) 
Wu N, Dempsey J, Yehl PM, Dovletoglou A, Ellison D, Wyvratt J, Anal. Chim. Acta, 523(2), 149 (2004) 
Gritti F, Piatkowski W, Guiochon G, J. Chromatogr. A, 983(1), 51 (2003) 

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.