ISSN: 0304-128X ISSN: 2233-9558
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
korean
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received December 5, 2005
Accepted February 3, 2006
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

자성 미세입자에의 항체 고정화 방법이 면역결합반응에 미치는 영향

Effect of Antibody Immobilization Method to Magnetic Micro Beads on its Immunobinding Characteristics

한양대학교 화학공학과 생물공정연구실, 425-791 경기도 안산시 상록구 사 1동 1271 1한양대학교 응용화학과, 425-791 경기도 안산시 상록구 사 1동 1271
Bioprocessing Research Laboratory, Department of Chemical Engineering, Hanyang University, 1271, Sa 1-dong, Sangnok-gu, Ansan 426-791, Korea 1Department of Applied Chemistry, Hanyang University, 1271, Sa 1-dong, Sangnok-gu, Ansan 426-791, Korea
Korean Chemical Engineering Research, February 2006, 44(1), 65-72(8), NONE Epub 9 March 2006
downloadDownload PDF

Abstract

자력을 이용한 분리기술의 장점을 이용하여 여러 가지 불순물들이 섞여 있는 현탁 용액으로부터 자성입자를 이용하여 목적 단백질만을 얻어낼 수 있는 기술의 가능성에 대하여 알아보고자 하였다. 자성입자를 이용하는 경우에는 (1) 자성입자 표면에 리간드 고정화, (2) ligand(리간드)와 목적 물질과의 특이적 결합, (3) 자력을 이용한 자성입자의 분리, (4) 목적 물질의 탈착 그리고 (5) 자성입자의 재사용 순서로 진행되어 여러 단계의 공정을 단순화시킬 수 있다. 이러한 자성입자를 이용한 방법은 효율성, 단순성, 까다롭지 않은 조건, 자동화의 용이성, 비용의 저렴함으로 인해 관심이 증대되고 있다. 본 연구에서는 표면이 카르복실기로 처리된 자성입자에 IgG 항체를 고정화시킨 후 IgG 를 목적 단백질로 하여 이를 분리해내고자 하였다. 이를 위하여 자성입자 표면에 다른 물질과의 비특이적 결합이 일어나지 않을 조건에 대하여 확인해 보았으며, IgG 항체를 배향성 고정화시켜 자성입자가 목적 단백질과 보다 효과적으로 결합하여 목적 단백질인 IgG만을 선택적으로 분리해 낼 수 있는지에 대하여 알아보았다. 높은 pH를 사 용할 경우 비특이적 흡착을 줄일 수 있었으며, IgG 항체 고정화된 자성입자를 사용할 경우 목적 단백질인 IgG와 선택적으로 반응함을 알 수 있었다. IgG 항체의 고정화에서 Fc지역 C-terminus에 인접해 있는 탄수화물 부분을 이용하여 배향성을 준 경우, IgG 항체 내의 아민기와 고정화시키는 비배향성 고정화 방법보다 항원과의 결합능력이 약 2배 높았다.
Recent technical advances in the biorecognition engineering and the microparticle fabrication may enable us to develop the single step purification using magnetic particle, because of its simplicity, efficacy, ease of automation, and process economics. In this study, we used commercial magnetic particles from Seradyn, Inc. (Indianapolis, USA). It was ca. 2.8 micron in diameter, consisted of polystyrene core and magnetite coating, and its surface had carboxyl groups. The model, capture protein was IgG and anti-IgG was used as the ligand molecule. We studied the different surfaces (‘nude’, ester-activated, and anti-IgG coated) for their biorecognition of IgG. At a high pH condition, we could reduce non-specific binding. Also anti-IgG immobilized magnetic particle could capture IgG more selectively. We attempted ‘oriented immobilization’ of anti-IgG, in which the polysaccharides moiety near the C-terminus was selectively oxidized and linked to the hydrazine-coated MP, to improve the efficacy of biorecognitive binding. Using this method, the IgG capturing ability was improved by ca. 2 fold. From the binary mixture of the IgG-insulin, IgG could be more selectively captured. In summary, the oriented immobilization of oxidized anti-IgG proved to be as effective as the streptavidin-biotin system and yet simpler and cost-effective. This immobilization method can find its applications in protein biochips and biotargeting.

References

Hubbuch JJ, Thomas ORT, Biotechnol. Bioeng., 79(3), 301 (2002) 
Yoo EM, Chintalacharuvu KR, Penichet ML, J. Immunol. Methods, 261, 1 (2002)
Turkova J, J. Chromatogr. B, 722, 11 (1999)
Wimalasena RL, Wilson GS, J. Chromatogra., 572, 85 (1991)
Hermanson GT, Bioconjugate Techniques, pp. 115, Academic press, New York, USA (1996)
Bilkoa Z, Mazurova JC, Horak D, Turkova J, J. Chromatogr. A, 852, 141 (1999) 
Babashak JV, Phillips TM, J. Chromatogra., 444, 21 (1998)
Abudiab T, Beitle RR, J. Chromatogr. A, 795, 211 (1998) 
Peng ZG, Hidajat K, Uddin MS, J. Colloid Interface Sci., 271(2), 277 (2004) 
Kandimalla VB, Neeta NS, Karanth NG, Thakur MS, Roshini KR Rani BEA, Pasha A, Karanth NGK, Biosens. Bioelectron., 20, 903 (2004)
Orthner CL, Highsmith FA, Tharakan J, J. Chromatogr., 558, 55 (1991) 
Nelson RW, Nedelkov D, Tubbs KA, BIA Journal, 7, 25 (2000)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Chemical Engineering Research 상단으로