ISSN: 0304-128X ISSN: 2233-9558
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
korean
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received May 19, 2010
Accepted June 22, 2010
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

축전식 탈염 시스템을 위한 셀 구조에 관한 연구

A Study on the Cell Structure for Capacitive Deionization System

광주과학기술원 환경공학부, 500-712 광주광역시 북구 첨단과기로 261
School of Environmental Science and Engineering, Gwangju Institute of Science and Technology(GIST), 261 Cheomdan-Gwagiro, Buk-gu, Gwangju 500-712, Korea
shmoon@gist.ac.kr
Korean Chemical Engineering Research, December 2010, 48(6), 791-794(4), NONE Epub 11 January 2011
downloadDownload PDF

Abstract

축전식 전기탈이온(Capacitive deionization: CDI) 시스템을 실제공정에 적용하기 위하여 대용량 제작이 가능하며 높은 처리 효율을 갖는 셀 구조 연구가 필요하다. 본 연구에서는 대용량 제작을 위하여 낮은 수압으로 운전할 수 있는 병렬형 구조와 처리효율을 증가시키기 위하여 집중형 유로를 동시에 적용하여 설계하고 성능 평가하였다. 설계한 유로 구조의 유입수 흐름을 확인하기 위하여 유체역학적 모델링이 가능한 COMSOL프로그램을 사용하여 집중형 유로가 형성되는 것을 확인하였고, 염 제거 효율을 확인하기 위하여 단위 셀과 20층으로 용량 증축된 스택을 사용하여 CDI 운전을 통한 제거효율을 확인하였다. 그 결과 210 cm2 면적의 단위 셀에서는 18 ml/min의 유량조건에서 1.1 psi의 수압으로 70.8%의 제거효율을 보였으며, 20층으로 용량 증축된 셀에서는 유량을 20배로 늘린 360 ml/min의 유량조건에_x000D_ 서 1.3~1.5 psi의 수압으로 75.6%의 제거효율을 확인할 수 있었다. 연구된 유로 설계는 대용량 시스템을 제작하는데 있어서 적합한 병렬형 구조이며 효율적인 탈염을 할 수 있는 집중형 유로로 설계되어 실제공정에 적용할 수 있는 구조임을 확인할 수 있었다.
This study presents channel design of a CDI stack to achieve high removal efficiency in a large scale by applying parallel flow structure with a concentrated stream. The flow pattern in the stack was simulated by COMSOL Multiphysics program. To prove the salt removal performance, a unit cell and 20 cell stacks were tested at a flow rate condition of 18 ml/min and 360 ml/min, respectively. The removal efficiencies of the unit cell and the 20 cell stacks were obtained as 70.8 % and 75.6 %, respectively, with 100 mg/L sodium chloride solution. During the operation of cell_x000D_ test, water pressures of unit cell and 20 cell pair stack maintained in the ranges of 1.1 psi and 1.3~1.5 psi, respectively. It was demonstrated that the parallel cell structure with two concentrated streams can be employed in a large scale CDI for salt removal.

References

Kim YJ, Choi JH, Water Res., 44, 990 (2010)
Seo SJ, Jeon H, Lee JK, Kim GY, Park D, Nojima H, Lee J, Moon SH, Water Res., 44, 2267 (2010)
Farmer JC, US Patent No. 5,954,937 (1999)
Shiue LR, US patent No. 6,66,643 B2 (2003)
D.Andelman M, US Patent No. 6,709,560 B2 (2004)
Lee JB, Park KK, Eum HM, Lee CW, Desalination, 196(1-3), 125 (2006)
Afkhami A, Madrakian T, Karimi Z, J. Hazard. Mater., 144(1-2), 427 (2007)
Huang CC, Su YJ, J. Hazard. Mater., 175, 477 (2010)
Jung HH, Hwang SW, Hyun SH, Kang-Ho L, Kim GT, Desalination, 216(1-3), 377 (2007)
Akhtar N, Decent SP, Loghin D, Kendall K, Int. J. Hydrog. Energy, 34, 8645 (2009)
Dermentzis K, Ouzounis K, Electrochim. Acta, 53(24), 7123 (2008)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Chemical Engineering Research 상단으로