ISSN: 0304-128X ISSN: 2233-9558
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
korean
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received March 9, 2011
Accepted April 4, 2011
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

아연도금강판의 방식을 위한 새로운 방청안료인 이온 교환된 제올라이트의 방청 성능

Anti-Corrosion Performance of the Novel Pigment, Ion-Exchanged Zeolite for the Protection of Galvanized Steel

포항공과대학교 철강대학원, 790-784 경북 포항시 남구 효자동 산 31 1포스코강판, 790-705 경북 포항시 남구 장흥동 470 2부경대학교 공업화학과, 608-739 부산시 남구 용당동 산 100
Graduate Institute of Ferrous Technology, Postech, San 31, Hyoja-dong, Nam-gu, Pohang, Gyeongbuk 790-784, Korea 1POSCO Coated & Color Steel Co., Ltd., 470 Janghung-dong, Nam-gu, Pohang, Gyeongbuk 790-705, Korea 2Department of Industral Chemistry, Pukyong National University, San 100, Yongdang-dong, Nam-gu, Busan 608-739, Korea
jongpark@postech.ac.kr
Korean Chemical Engineering Research, December 2011, 49(6), 745-751(7), NONE Epub 25 November 2011
downloadDownload PDF

Abstract

내부식성이 강화된 새로운 방청안료를 개발하기 위한 연구의 일환으로, 본 연구에서는 높은 내부식성을 제공하는 아연 및 세륨 이온 교환된 제올라이트를 도입하였다. 그리고 이온교환 제올라이트를 이용하여 프라이머 도료 제조 및 도장을 수행한 후, 그것의 방식성능을 측정하였다. 도장을 위한 금속 기재는 아연도금(galvanized, GI) 강판이었고, 도장된 강판의 방식성능은 electrochemical impedance spectroscopy(EIS)와 scanning vibrating electrode technique(SVET)으로 측정되었다. EIS 및 절단면의 내부식성을 확인하기 위한 SVET 측정으로부터 세륨이온 교환된 제올라이트가 가장 높은 효율을 제시하였고, 아연 및 세륨 이온 교환된 제올라이트의 경우 GI 강판에 대하여 cathodic 부식 방지제로 기_x000D_ 여함을 확인할 수 있었다.
In this study, zinc or cerium exchanged zeolite was introduced to develop a novel anti-corrosion pigment. The primer paint was made using them and was coated on galvanized(GI) steel. The anti-corrosion performance was measured using electrochemical impedance spectroscopy(EIS). And scanning vibrating electrode technique(SVET) was employed to observe the cut-edge corrosion process of the coated GI steel. From EIS and SVET results, it could be confirmed that Ce ion-exchanged zeolite showed the anti-corrosion performance higher than Shieldex C303 and Zn ionexchanged zeolite. Finally, it was found that metal ion-exchanged zeolite may provide new possibility as the smart cathodic corrosion inhibitor delivery systems on galvanized steels.

References

Howard RL, Zin IM, Scantlebury JD, Lyon SB, Prog. Org. Coat., 37, 83 (1999)
Delucchi M, Barbucci A, Cerisola G, Electrochim. Acta, 44(24), 4297 (1999)
Bohm S, McMurray HN, Powell SM, Worsley DA, Mater. Corros., 52, 896 (2001)
Simoes AM, Torres J, Picciochi R, Fernandes JCS, Electrochim. Acta, 54(15), 3857 (2009)
Hwang HD, Lee YH, Kim HJ, Noh SM, Nam JH, Park JM, Kim JH, Korean Ind. Chem. News, 13(6), 36 (2010)
Deflorian F, Felhosi I, Rossi S, Fedrizzi L, Bonora PL, Macromol. Symp., 187, 87 (2002)
Williams G, McMurray HN, Loveridge MJ, Electrochim. Acta, 55(5), 1740 (2010)
Powell SM, McMurray HN, Worsley DA, Corrosion., 55, 1040 (1999)
Williams G, McMurray HN, Worsley DA, J. Electrochem. Soc., 149(4), B154 (2002)
Cheng XL, Wang ZB, Yan YS, Electrochem. Solid State Lett., 4(5), B23 (2001)
Mitra A, Wang ZB, Cao TG, Wang HT, Huang LM, Yan YS, J. Electrochem. Soc., 149(10), B472 (2002)
Beving DE, McDonnell AMP, Yang WS, Yan YS, J. Electrochem. Soc., 153(8), B325 (2006)
Cai R, Yan Y, Corrosion., 64, 271 (2008)
Lew CM, Cai R, Yan Y, Acc. Chem. Res., 43, 210 (2010)
Haron MJ, Rahim FA, Abdullah AH, Hussein MZ, Kassim A, Mater. Sci. Eng., B., 149, 204 (2008)
Fedrizzi L, Deflorian F, Boni G, Bonora PL, Pasini E, Prog. Org. Coat., 29, 89 (1996)
Mansfeld F, Tsai CH, Corrosion., 47, 958 (1991)
Aldykiewicz AJ, Davenport AJ, Isaacs HS, J. Electrochem. Soc., 143(1), 147 (1996)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Chemical Engineering Research 상단으로