articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

바나듐 레독스 흐름전지용 Poly(arylene ether sulfone) 막의 특성

Characteristics of Poly(arylene ether sulfone) Membrane for Vanadium Redox Flow Battery

순천대학교 화학공학과, 540-742 전남 순천시 매곡동 315 1코오롱인더스트리(주) Eco연구소 중앙기술원, 446-797 경기도 용인시 기흥구 마북동 207-2 2(주)ETIS, 415-813 경기도 김포시 고천읍 풍곡리 431-1
Department of Chemical Engineering, Sunchon National University, 315 Maegok-dong, Suncheon, Chonnam 540-742, Korea 1Kolon Research Institute, 207-2 Mabuk-dong, Giheung-gu, Youngin, Gyeonggi 446-797, Korea 2ETIS Co, Punggok-ri, Gochon-eup, Gimpo-si, Gyeonggi 415-813, Korea
parkkp@sunchon.ac.kr
Korean Chemical Engineering Research, December 2013, 51(6), 671-676(6), 10.9713/kcer.2013.51.6.671 Epub 2 December 2013
downloadDownload PDF

Abstract

최근에 대용량 에너지 저장 시스템으로 레독스 흐름전지(Redox Flow Battery, RFB)가 활발히 연구·개발되고 있다. 불소계막을 대신할 저가의 탄화수소막이 RFB막으로 주목받고 있다. 본 연구에서는 Poly(arylene ether sulfone) (PAES) 막을 사용해 고가의 불소계막과 그 특성을 바나듐 레독스 흐름전지(VRB, Vanadium Redox Flow Battery)조건에서 비교하였다. 바나듐 이온투과도, 이온 교환 용량, OCV 변화, 팽윤, 충·방전 곡선, 에너지 효율 등을 측정했다. PAES 막은 Nafion 117막에 비해 바나듐 이온투과도가 낮고, 이온교환용량은 커서 Nafion 117을 사용한 RFB보다 에너지 효율이 높았다.
Recently, there are many efforts focused on development of Redox Flow Battery (RFB) for large energy storage system. Economical hydrocarbon membranes alternative to fluorinated membranes for RFB membrane are receiving attention. In this study, characteristics of poly(arylene ether sulfone) (PAES) were compared with expensive fluorinated membrane at VRB (Vanadium Redox Flow Battery) operation condition. Permeability of vanadium ion through membrane, ion exchange capacity (IEC), change of OCV, swelling, charge-discharge curves and energy efficiency were measured. PAES membrane showed lower permeability of vanadium ion, higher IEC and then higher energy efficiency compared with Nafion 117 membranes.

References

de Leon CP, Frias-Ferrer A, Gonzalez-Garcia J, Szanto DA, Walsh FC, J. Power Sources, 160(1), 716 (2006)
Prifti H, Parasuraman A, Winardi S, Lim TM, Maria KS, Membranes., 2, 275 (2012)
Zhang H, Zhang H, Li X, Mai Z, Wei W, Li Y, J. Power Sources., 217, 309 (2012)
Cy F, Kim S, Stains R, Wei X, Li L, Yang ZG, Electrochem. Commun., 20, 48 (2012)
Hwang GJ, Ohya H, J. Membr. Sci., 120(1), 55 (1996)
Luo QT, Zhang HM, Chen J, You DJ, Sun CX, Zhang Y, J. Membr. Sci., 325(2), 553 (2008)
Park SG, Kwak NS, Hwang CW, Park HM, Hwang TS, J. Membr. Sci., 423-424, 429 (2012)
So SY, Yoon YJ, Kim TH, Yoon K, Hong YT, J. Membr. Sci., 381(1-2), 204 (2011)
Zhang B, Zhang S, Xing D, Han R, Yin C, Jian X, J. Power Sources., 217, 296 (2012)
Lawrence J, Yamaguchi T, J. Membr. Sci., 325(2), 633 (2008)
Lee H, Kim T, Sim W, Kim S, Ahn B, Lim T, Park K, Korean J. Chem. Eng., 28(2), 487 (2011)
Song J, Kim S, Ahn B, Ko J, Park K, Korean Chem. Eng. Res., 51(1), 68 (2013)
Luo QT, Zhang HM, Chen J, You DJ, Sun CX, Zhang Y, J. Membr. Sci., 325(2), 553 (2008)
Zhao P, Zhang HM, Zhou HT, Chen J, Gao SJ, Yi BL, J. Power Sources, 162(2), 1416 (2006)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.