articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

과산화수소 증기를 이용한 유사화학작용제의 제독

Decontamination of Chemical Warfare Agent Simulants using Vapor-phase Hydrogen Peroxide

삼양화학공업(주), 경기도 안양시 만안구 석수동 251-3 1국방과학연구소, 대전시 유성구 유성우체국 사서함 35호
Samyangchemical Co., Ltd., 251-3 Seoksu-dong, Manan-gu, Anyang-si, Gyeonggi 430-852, Korea 1Agency for Defense Development, P.O.Box 35, Yuseong-gu, Daejeon 305-152, Korea
Korean Chemical Engineering Research, June 2014, 52(3), 360-365(6), 10.9713/kcer.2014.52.3.360 Epub 2 June 2014
downloadDownload PDF

Abstract

과산화수소 증기는 기존 염소계열의 멸균제에 비해 부식성이 낮아 제약 및 의료 분야의 실내멸균제로 사용되며, 암모니아 가스 추가 시 화학작용제의 제독성능이 있다고 알려져 있다. 본 연구에서는 과산화수소 증기를 이용하여 HD, GD, VX의 유사작용제인 CEPS, DFP, dimethoate 등에 대한 제독효율을 확인하였다. 이를 위해 자체 구성한 과산화수소 기화장치에서 발생시킨 증기를 제독챔버에 주입하여 반응시간을 유지하였다. 제독 후 잔류물을 GC/MS로 분석한 후 제독효율을 계산하였고, 각각의 유사작용제에 대한 반응 생성물을 통해서 화학작용제의 반응 메카니즘과 유사함을 확인하였다. 실험결과 CEPS는 30%의 상대습도에서 60분의 반응시간에 완전제독 되었고, 암모니아 가스 주입의 동반하에서 DFP는 30분, dimethoate는 150분의 반응시간에 완전제독되었다.
Vapor-phase hydrogen peroxide(VPHP) has been used as a sterilant in the field of medical and pharmaceutical application due to low corrosive than chlorine contained sterilant. In addition, it is well known that VPHP is effective for decontamination of chemical warfare agents by adding ammonia gas. In this study, the decontamination efficiency was confirmed about CEPS, DFP and dimethoate as simulants of HD, GD and VX using VPHP respectively. For this purpose, VPHP generated from self configured device was injected into decontamination chamber and maintained for reaction time. After the decontamination, the residues are analyzed by GC/MS and decontamination efficiency was calculated. Through by-product for each simulants, the similarities in reaction mechanism of chemical warfare agents were confirmed. CEPS was completely decontaminated at 30% relative humidity within 60 min. By adding ammonia gas, DFP and dimethoate were completely decontaminated within 30 and 150 min respectively.

References

Introduction, The Chemical Weapons Convention(CWC), http://www.opcw.org/.
Kim JK, Kim IS, Shin KS, Journal of the Institute of Electronics Engineers of Korea, 45, 48 (2008)
“Compilation of Available Date on Building Decontamination Alternatives,” EPA/600/R-05/036 (2005)
“Joint Service Sensitive Equipment Decontamination(JSSED), Block I Systems Technology Overview,” Report PAO-01-432 (2000)
Wagner GW, Sorrick DC, Procell LR, Brickhouse MD, Mcvey IF, Schwartz LI, Langmuir, 23(3), 1178 (2007)
Svrcek J, Marhoul A, Kacer P, Kuzma M, Panek L, Cerveny L, J. Chem. Technol. Biotechnol., 85(9), 1284 (2010)
Shannon L, Detlef RU, Morton A, Critical Reviews in Environmental Science and Technology, 38, 112 (2008)
Lee BM, Veriansyah B, Kim SH, Kim JD, Lee YW, Korean J. Chem. Eng., 22(4), 579 (2005)
Weres O, Pocekay J, “Decontamination System Utilizing Hydrogen Peroxide UV Light and Catalytic Surfaces,” CRDECCR-111 (1992)
D’Agostino PA, Hancock JR, Provost LR, J. Chromatogr A, 912, 291 (2001)
Read RW, Black RM, J. Chromatogr A, 862, 169 (1999)
Kanu AB, Haigh PE, Hill HH, Anal. Chim. Acta, 553, 148 (2005)
Lebedev AT, Toxicol. and Applied Pharmacy, 207, 451 (2005)
Lee YH, Lee JC, Choi S, Hong D, Korean Chem. Eng. Res., 45(3), 291 (2007)
Harvey SP, Kolakowski JE, Sumpter KB, Szafraniec LL, Harley MV, Rohrbaugh DK, “Hydrolysis of 15 wt% HD in Water,” ECBC-TR-121, Chemical Biologcal Center, APG, U.S.A. (2000)
Wagner GW, Yang YC, Ind. Eng. Chem. Res., 41(8), 1925 (2002)
Lee NW, Richard GZ, John AG, George LB, David MC, Environ. Sci. Technol., 11(1), 89 (1977)
Oleh W, et al., “Decontamination System Utilizing Hydrogen Peroxide, UV Light and Catalytic Surfaces,” CRDEC-CR-111 (1992)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Chemical Engineering Research 상단으로