ISSN: 0304-128X ISSN: 2233-9558
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
korean
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
Publication history
Received August 6, 2015
Accepted September 17, 2015
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

새로운 가교제를 적용한 촉매를 이용한 글루코스 센서의 성능향상 연구

A Study on Performance Improvement of Glucose Sensor Adopting a Catalyst Using New Cross Liker

서울과학기술대학교 에너지환경대학원, 01811 서울특별시 노원구 공릉로 232
Graduate School of Energy and Environment, Seoul National University of Science and Technology, 232 Gongreung-ro, Nowon-gu, Seoul 01811, Korea
Korean Chemical Engineering Research, December 2015, 53(6), 802-807(6), 10.9713/kcer.2015.53.6.802 Epub 30 November 2015
downloadDownload PDF

Abstract

본 논문에서는 글루코스산화제, polyethyleneimine(PEI) 및 탄소나노튜브 간 물리적 흡착으로 제조된 촉매(GOx/PEI/CNT)에 새로운 가교제인 terephthalaldehyde(TPA)를 첨가하여 민감도 및 안정성이 개선된 글루코스 센서 촉매를 합성하여, 감지능 및 안정성 개선효과를 확인하였다. 새로운 가교제를 포함한 바이오 촉매는, 글루코스산화제 및 polyethyeleneimine의 관능기와 TPA의 관능기간 알돌축합반응에 의해 생성되었고, 이를 통해 생성된 새로운 전자전달구조는 글루코스의 산화반응을 촉진시켰다. 이러한 촉매활성은 전기화학적 평가를 통해 정량적으로 평가하였으며 그 결과 41.1 μAcm-2mM-1의 글루코스 민감도를 얻을 수 있었다. 또한 가교제와 글루코스산화제 및 polyethyeleneimine간의 화학반응의 형성에 의해 글루코스 산화제의 외부 손실을 최소화 하여, 센서 안정성 향상에도 크게 기여하였다. 안정성 평가를 한 결과, 3주간의 주기적인 촉매 활성 측정후에 94.6% 활성이 유지됨을 확인하였다.
In this study, we synthesized a new biocatalyst consisting of glucose oxidase (GOx), polyethyleneimine (PEI) and carbon nanotube (CNT) with addition of terephthalaldehyde (TPA) (TPA/GOx/PEI/CNT) for fabrication of glucose sensor that shows improved sensing ability and stability compared with that using other biocatalysts. Main bonding of the new TPA/GOx/PEI/CNT catalyst is formed by Aldol condensation reaction of functional end groups between GOx/PEI and TPA. Such formed bonding structure promotes oxidation reaction of glucose. Catalytic activity of TPA/GOx/PEI/CNT is evaluated quantitatively by electrochemical measurements. As a result of that, large sensitivity value of 41 μAcm-2mM-1 is gained. Regarding biosensor stability of TPA/GOx/PEI/CNT catalyst, covalent bonding formed between GOx/PEI and TPA prevents GOx molecules from becoming leaching-out and contributes improvement in biosensor stability. With estimation of the biosensor stability, it is found that the TPA/GOx/PEI/CNT catalyst keeps 94.6% of its initial activity even after three weeks.

References

International Diabetes Federation, “Diabetes Atlas. 2nd ed.,” International Diabetes Federation, 17-71(2003).
Yun KE, Park MJ, Park HS, Int. J. Clin. Pract., 61(1), 39 (2007)
Bankar SB, Bule MV, Singhal RS, Ananthanarayan L, Biotechnol. Adv., 27, 489 (2009)
Rad AS, Ardjmand M, Jahanshahi M, Safekordi AA, Korean J. Chem. Eng., 29(8), 1063 (2012)
Park HG, Hwang U, Kim IH, Korean Chem. Eng. Res., 39, 512 (2001)
Kim H, Jeong NJ, Lee SJ, Song KS, Korean J. Chem. Eng., 25(3), 443 (2008)
Yu HR, Kim JG, Im JS, Bae TS, Lee YS, J. Ind. Eng. Chem., 18(2), 674 (2012)
Sheldon RA, Appl. Microbiol. Biotechnol., 92(3), 467 (2011)
Chung Y, Hyun KH, Kwon Y, “Fabrication of Biofuel Cell Improved by π-conjugated Electron Pathway Effect Induced from a new Enzyme Catalyst Employing Terephtalal Dehyde,” Nanoscale. Accepted.
Hyun KH, Han SW, Koh WG, Kwon Y, J. Power Sources, 286, 197 (2015)
Ramanavicius A, Kausaite A, Ramanaviciene A, Biosens. Bioelectron., 20, 1962 (2005)
Kaczmarczyk B, J. Mol. Struct., 1048, 179 (2013)
Kurihara T, Oba N, Mori Y, Tomaru S, Kaino T, J. Appl. Phys., 70, 17 (1991)
Dobrikov G, Vacuum, 76, 227 (2004)
Xiao Y, Patolsky F, Katz E, Hainfeld JF, Willner I, Science, 299, 1877 (2003)
Zhang S, Wang N, Yu H, Niu Y, Sun C, Bioelectrochemistry, 67, 15 (2005)
Yan XB, Chenn XJ, Tay BK, Khor KA, Electrochem. Commun., 9, 1269 (2007)
Liu Q, Lu XB, Li J, Yao X, Li JH, Biosens. Bioelectron., 22, 3203 (2007)
Hyun K, Han SW, Koh WG, Kwon Y, Int. J. Hydrog. Energy, 40(5), 2199 (2015)
Cai C, Chen J, Anal. Biochem., 332, 75 (2004)
Bahulekar R, Ayyangar NR, Ponrathnam S, Enzyme Microb. Technol., 13, 858 (1991)
Xiong MP, Biomaterials, 28, 4889 (2007)

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Chemical Engineering Research 상단으로