Articles & Issues
- Language
- english
- Conflict of Interest
- In relation to this article, we declare that there is no conflict of interest.
- Publication history
-
Received March 27, 2017
Accepted April 10, 2017
- This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.
All issues
Fabrication of Hemoglobin/Silver Nanoparticle Heterolayer for Electrochemical Signal-enhanced Bioelectronic Application
Department of Chemical Engineering, Kwangwoon University, 20, Kwangwoon-ro, Nowon-gu, Seoul, 01897, Korea 1Department of Chemical & Biomolecular Engineering, Sogang University, 35, Baekbeom-ro, Mapo-gu, Seoul, 04107, Korea
jwchoi@sogang.ac.kr
Korean Chemical Engineering Research, August 2017, 55(4), 556-560(5), 10.9713/kcer.2017.55.4.556 Epub 4 August 2017
Download PDF
Abstract
A hemoglobin/silver nanoparticle heterolayer was fabricated for bioelectronic device with electrochemical signal-enhancement effect. As a device element, a hemoglobin, the metalloprotein, contained the heme group that showed the redox property was introduced for charge storage element. For electron transfer facilitation, a silver nanoparticle was introduced for electrochemical signal facilitation, the hemoglobin was immobilized onto Au substrate using chemical linker 6-mercaptohexanoic acid (6-MHA). Then, the silver nanoparticle was immobilized onto fabricated hemoglobin/6-MHA heterolayers by layer-by-layer (LbL) method. The surface morphology and surface roughness of fabricated heterolayer were investigated by atomic force microscopy (AFM). The redox property of hemoglobin/silver nanoparticle heterolayer was investigated by a cyclic voltammetry (CV) experiment for obtaining an oxidation potential and reduction potential. Moreover, for the assessing charge storage function, a chronoamperometry (CA) experiment was conducted to hemoglobin/silver nanoparticle-modified heterolayer electrode using oxidation and reduction potentials, respectively. Based on the results, the fabricated hemoglobin/silver nanoparticle heterolayer showed that an increased charge storage effect compared to hemoglobin monolayer-modified electrode.
Keywords
References
Lu W, Lieber CM, Nat. Mater., 6(11), 841 (2007)
Petty MC, Molecular Electronics: From Principles to Practice, 1st ed., Wiley, Chichester(2007).
Noy A, Adv. Mater., 23(7), 807 (2011)
Willner I, Katz E, Bioelectronics: From Theory to Applications, 1st ed., Wiley-VCH, Weinheim(2005).
Heath JR, Annu. Rev. Mater. Res., 39, 1 (2009)
Katz E, Privman V, Chem. Soc. Rev., 39, 1935 (2010)
Lee J, Cho J, Park C, Korean Chem. Eng. Res., 55(1), 115 (2017)
Fujibayashi K, Hariadi R, Park SH, Winfree E, Murata S, Nano Lett., 8, 1791 (2008)
Qian L, Winfree E, Bruck J, Nature, 475(7356), 368 (2011)
Tseng RJ, Tsai CL, Ma LP, Ouyang JY, Nat. Nanotechnol., 1(1), 72 (2006)
Win MN, Smolke CD, Science, 322, 456 (2008)
Baron R, Lioubashevski O, Katz E, Niazov T, Wilner I, Angew. Chem.-Int. Edit., 45, 1572 (2006)
Cho B, Song S, Ji Y, Kim TW, Lee T, Adv. Funct. Mater., 21(15), 2806 (2011)
Choi HG, Jung WC, Min J, Lee WH, Choi JW, Biosens. Bioelectron., 16, 925 (2001)
Min J, Choi HG, Oh BK, Lee WH, Paek SH, Choi JW, Biosens. Bioelectron., 16, 917 (2001)
Choi JW, Fujihira M, Appl. Phys. Lett., 84, 2187 (2004)
Choi JW, Lee BH, Korean Chem. Eng. Res., 44(1), 1 (2006)
Lee T, Kim SU, Min J, Choi JW, Adv. Mater., 22(4), 510 (2010)
Lee T, Min J, Kim SU, Choi JW, Biomaterials, 32, 3815 (2011)
Lee T, El-Said WA, Min J, Choi JW, Biosens. Bioelectron., 26, 2304 (2011)
Lee T, Yagati AK, Pi F, Sharma A, Choi JW Guo P, ACS Nano, 9, 6675 (2015)
Schechter AN, Blood, 112, 3927 (2008)
Han X, Cheng W, Zhang Z, Dong S, Wang E, Biochim. Biophys. Acta-Bioenerg., 1556, 273 (2002)
Lee T, Yagati AK, Min J, Choi JW, Adv. Funct. Mater., 24(12), 1781 (2014)
Petty MC, Molecular Electronics: From Principles to Practice, 1st ed., Wiley, Chichester(2007).
Noy A, Adv. Mater., 23(7), 807 (2011)
Willner I, Katz E, Bioelectronics: From Theory to Applications, 1st ed., Wiley-VCH, Weinheim(2005).
Heath JR, Annu. Rev. Mater. Res., 39, 1 (2009)
Katz E, Privman V, Chem. Soc. Rev., 39, 1935 (2010)
Lee J, Cho J, Park C, Korean Chem. Eng. Res., 55(1), 115 (2017)
Fujibayashi K, Hariadi R, Park SH, Winfree E, Murata S, Nano Lett., 8, 1791 (2008)
Qian L, Winfree E, Bruck J, Nature, 475(7356), 368 (2011)
Tseng RJ, Tsai CL, Ma LP, Ouyang JY, Nat. Nanotechnol., 1(1), 72 (2006)
Win MN, Smolke CD, Science, 322, 456 (2008)
Baron R, Lioubashevski O, Katz E, Niazov T, Wilner I, Angew. Chem.-Int. Edit., 45, 1572 (2006)
Cho B, Song S, Ji Y, Kim TW, Lee T, Adv. Funct. Mater., 21(15), 2806 (2011)
Choi HG, Jung WC, Min J, Lee WH, Choi JW, Biosens. Bioelectron., 16, 925 (2001)
Min J, Choi HG, Oh BK, Lee WH, Paek SH, Choi JW, Biosens. Bioelectron., 16, 917 (2001)
Choi JW, Fujihira M, Appl. Phys. Lett., 84, 2187 (2004)
Choi JW, Lee BH, Korean Chem. Eng. Res., 44(1), 1 (2006)
Lee T, Kim SU, Min J, Choi JW, Adv. Mater., 22(4), 510 (2010)
Lee T, Min J, Kim SU, Choi JW, Biomaterials, 32, 3815 (2011)
Lee T, El-Said WA, Min J, Choi JW, Biosens. Bioelectron., 26, 2304 (2011)
Lee T, Yagati AK, Pi F, Sharma A, Choi JW Guo P, ACS Nano, 9, 6675 (2015)
Schechter AN, Blood, 112, 3927 (2008)
Han X, Cheng W, Zhang Z, Dong S, Wang E, Biochim. Biophys. Acta-Bioenerg., 1556, 273 (2002)
Lee T, Yagati AK, Min J, Choi JW, Adv. Funct. Mater., 24(12), 1781 (2014)