articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

참깻묵의 자연발화온도와 활성화 에너지를 통한 화재 및 폭발의 위험성 평가

Assessment of the Risks of Fire and Explosion through the Spontaneous Ignition Temperature and Activation Energy of Sesame Seed Oil Cakes

부경대학교 소방공학과, 48513 부산광역시 남구 용소로 45 1국립과학수사연구원, 26460 강원도 원주시 입춘로 10
Department of Fire Protection Engineering, Pukyong National University, Busan, 48513, Korea 1National Forensic Service, 10, Ipchun-ro, Wonju-si, Gangwon-do, 26460, Korea
jwchoi@pknu.ac.kr
Korean Chemical Engineering Research, May 2021, 59(2), 225-231(7), 10.9713/kcer.2021.59.2.225 Epub 3 May 2021
downloadDownload PDF

Abstract

참깻묵은 4류 위험물 중 동식물류로서 기름을 추출하고 생성된 찌꺼기를 보관하는 중에 열이 축적되어 자연발화의 원인에 의해 화재가 발생되고 있다. 참깻묵의 자연발화에 대한 원인을 규명하기 위하여 시료용기의 두께(3 cm, 5 cm, 7 cm 및 14 cm)를 변화시켜 저장량에 따른 자연발화온도를 구한 결과 3 cm의 경우 180 °C, 5 cm의 경우160 °C, 7 cm의 경우 145 °C, 14 cm의 경우 130 °C 를 구하였다. 시료용기의 두께가 두꺼워질수록 발화한계온도는 낮아졌으며, 발화지연시간 및 최고온도에 도달하는 시간이 길어졌다. 또한 발화와 비발화의 평균온도인 발화한계온도에 의한 겉보기 활성화 에너지는 97.10 [kJ/mol]로서 참깻묵의 발화특성을 파악하였다.
Sesame seed oil cakes are classified as the animal or plant origin among the flammable liquids, and the fire occurs due to the spontaneous ignition through the accumulation of heat during the storage of residues after the extraction of sesame oil. In order to elucidate the cause of the spontaneous ignition of sesame seed oil cakes, the thickness (3 cm, 5 cm, 7 cm and 14 cm) of the sample container was varied, and the spontaneous ignition temperature was measured depending on the storage volume. Thus, the spontaneous ignition temperature was measured to be 180 °C at the thickness of 3 cm, 160 °C at 5 cm, 145 °C at 7 cm and 130 °C at 14 cm. As the thickness of the sample container increased, the critical ignition temperature decreased, and the induction time to spontaneous ignition and the time to reach the maximum temperature became longer. Furthermore, the apparent activation energy by the critical ignition temperature, which is the average temperature of ignition and non-ignition, was 97.10 [kJ/mol]. With these data, ignition characteristics of sesame seed oil cakes were determined.

References

Lee HP, Park YJ, Combustion Engineering, Hwasoomok, Korea, 114 (2015).
Choi JW, Jin SG, Fire Protection Safety Engineering, Hwasoomok, Korea, 40 (2018).
National Fire Data System : Fire Statistics, http://nfds.go.kr/stat/general.do.
Jo YG, Cases of Natural Ignition due to Heat Waves, National Forensic Service, https://www.kfpa.or.kr/webzine/201812/sub/disasters7.html.
Park JK, Kim RH, Jung MJ, Song SH, Yoon SC, Jun DW, Lee NH, J. of Korea Society of Waste Management, 36(4), 401 (2019).
Ministry of Food and Drug Safety : Edible Oils and Fats, https://www.foodsafetykorea.go.kr/foodcode/01_03.jsp?idx=28.
Lee HP, Kim DJ, Kim YC, Koo JH, et al., Hwasoomok, Korea, 714-715(2015).
Choi YJ, Kim JH, Choi JW, The Korean Institute of Chemical Engineers, 55(5), 623 (2017).
Jeong JH, Graduate School, Pukyong National Univ., Korea, 28-35(2019).
Yang Y, Li Z, Si L, Gu F, Zhou Y, Qi Q, Sun X, Arabian Journal for Science and Engineering, 42, 1358 (2017).
Choi JJ, Chungnam National Univ., Graduate School of Industry, Korea, 1 (2010).
Han OS, Lee KW, Korean Chem. Eng. Res., 54(3), 367 (2016)
Frank-Kamenetskii DA, Princeton University Press, NJ, USA, 202 (1955).
Kok MV, Pamir MR, J. Anal. Appl. Pyrolysis, 55(2), 185 (2000)
Lim WS, Choi JW, J. of the Korean Society of Safety, 22(5), 77 (2007).
Kim HS, Choi YJ, Choi JW, J. of the Korea Academia-Industrial Cooperation Society, 20(4), 590 (2019).
Kim HS, Choi YJ, Kim JH, Jeong PH, Choi JW, Fire Science and Engineering, 33(1), 7 (2019).
Choi JW, Fire Protection Chemical Experiment Report, Hwasoomok, Korea, 106 (2018).

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Chemical Engineering Research 상단으로