- This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.
All issues
가스법에 의한 염기성탄산 마그네슘 제조에 관한 연구 - 1. 염기성탄산 마그네슘의 건조에 관하여-
Preparation of Basic Magnesium Carbonate by Gas Method: 1. Drying of Basic Magnesium Carbonate
HWAHAK KONGHAK, December 1968, 6(4), 201-208(8), NONE
Download PDF
Abstract
The critical moisture content of basic magnesium carbonate has been determined to be about 150 %(D.B) based on the characteristic curve for drying, obtained by both laboratory and pilot plant Tunnel Dryer methods.
Temperature, humidity, flow rate, size and thickness of the feed material, and direction of air flow had large effect on drying in the constant rate period, but had little effect in the falling rate period.
The optimum operation condition for drying with tunnel dryer had also been investigated.
The tunnel dryer designed in this work had the following characteristics : critical moisture content : Wc=1.47, equilibrium moisture content, We=0.01 ; initial moisture content, W1=4.00 ; moisture content at time, W2=0.16 (t=9 hrs) : inlet air humidity=50 % at 20 ℃ ; out let air humidity=60 % at 70 ℃ ; preheated air temp.=120 ℃, overall heat efficiency, over 60 %.
Temperature, humidity, flow rate, size and thickness of the feed material, and direction of air flow had large effect on drying in the constant rate period, but had little effect in the falling rate period.
The optimum operation condition for drying with tunnel dryer had also been investigated.
The tunnel dryer designed in this work had the following characteristics : critical moisture content : Wc=1.47, equilibrium moisture content, We=0.01 ; initial moisture content, W1=4.00 ; moisture content at time, W2=0.16 (t=9 hrs) : inlet air humidity=50 % at 20 ℃ ; out let air humidity=60 % at 70 ℃ ; preheated air temp.=120 ℃, overall heat efficiency, over 60 %.