- This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.
All issues
수직관 열전달에 있어서의 동응답
A Study of Dynamic Response for a Vertical Tube Heat Transfer
HWAHAK KONGHAK, June 1964, 2(1), 9-16(8), NONE
Download PDF
Abstract
The dynamic responses of the temperatures of the outlet water and the wall for a vertical tube heat exchanger, were studied as a function of the sinusoidal change in the inlet water temperature.
The experimental response data for the outlet water temperature were compared with the calculated data from the derived equation. The comparison was shown to be in good agreement between the experiment and the theory in the present range of the experiment.
The inlet water-to-wall temperature transfer function was derived, and the theoretical frequency response characteristics were compared with the experimental data. The experimental data were lower than those predicted from the theory.
The experimental response data for the outlet water temperature were compared with the calculated data from the derived equation. The comparison was shown to be in good agreement between the experiment and the theory in the present range of the experiment.
The inlet water-to-wall temperature transfer function was derived, and the theoretical frequency response characteristics were compared with the experimental data. The experimental data were lower than those predicted from the theory.