ISSN: 0304-128X ISSN: 2233-9558
Copyright © 2024 KICHE. All rights reserved

Articles & Issues

Language
korean
Conflict of Interest
In relation to this article, we declare that there is no conflict of interest.
articles This is an Open-Access article distributed under the terms of the Creative Commons Attribution Non-Commercial License (http://creativecommons.org/licenses/bync/3.0) which permits unrestricted non-commercial use, distribution, and reproduction in any medium, provided the original work is properly cited.
Copyright © KIChE. All rights reserved.

All issues

스코리아를 담체로 한 Biofilter에서 Benzene 제거 특성

Removal Characteristics of Benzene in the Biofilter Packed with Scoria

부경대학교 화학공학부, 608-739 부산시 남구 용당동 산100 1동의대학교 물질과학부, 614-714 부산시 부산진구 가야동 산24
Division of Chemical Engineering, Pukyong National University, San 100, Yongdang-dong, Nam-gu, Busan 608-739, Korea 1Division of Material Science, Dongeui University, San 24, Gaya-dong, Busanjin-gu, Busan 614-714, Korea
mglee@pknu.ac.kr
HWAHAK KONGHAK, December 2003, 41(6), 781-787(7), NONE
downloadDownload PDF

Abstract

제주도 스코리아를 충전한 바이오필터에서 기상 benzene의 생물분해능을 조사하였다. Benzene분해 미생물 균주는 Bacillus sp.를 사용하였다. 회분식 실험 결과로부터 benzene에 대한 Bacillus sp의 비증식 속도는 0.037 hr-1로 얻어졌다. 연속식 바이오필터 운전에서 benzene의 유입농도가 600 ppmv일 때 공탑접촉시간 (EBCT)가 20 sec 이상에서는 거의 100% 제거되었으며, EBCT를 10 sec로 낮추더라도 제거효율은 90%이상 유지되었다. Benzene에 대한 최대 제거용량은 720 g/m3·hr이었다. 약 200일 동안 연속 운전하였으나 전체적으로 드레인수의 pH는 6-7로 거의 일정하게 유지되었으며, 압력 강하는 평균 5 mm H2O로 낮은 압력 강하를 보였다. 층 깊이에 따른 benzene의 농도 변화는 1차 반응 모델식을 만족하였다.
The biodegradation of benzene vapor in the biofilter packed with scoria, which was from Jeju island, was investigated. Bacillus sp. was used as a benzene oxidizer. Batch experiment results showed that the specific growth rate of Bacillus species was 0.037 hr-1 for benzene. In the continuous biofilter operation, the empty bed contact time (EBCT) was changed from 5 to 60 sec with a fixed concentration of benzene at 600 ppmv. At the EBCTs up to 20 sec, the removal efficiency was over 99.9%. When the EBCT was further reduced to 10 and 5 sec, the removal efficiency decreased to 90% and 45%, respectively. The maximum capacity of benzene was 720 g/m3·hr. During the 200 days operation, the biofilter gave a stable removal efficiency such that the pH of a drain water was maintained at 6-7 and the pressure drop was about 5 mmH2O. The results for the benzene vapor concentration with respect to filter height followed the first order kinetics.

References

Arnold M, Reittu A, von Wright A, Martikainen PJ, Suihko ML, Appl. Microbiol. Biotechnol., 48(6), 738 (1997) 
Sukesan S, Watwood ME, Appl. Microbiol. Biotechnol., 48(5), 671 (1997) 
EPA IM, I/M Briefing Book, EPA-AA-EPSD-IM-94-1226, US EPA (1995)
EPA Air, National Air Pollutant Emission Trends (1900-1993), EPA-454/R-94-027 (1994)
KOSHA, "Hazardous Guide of Chemicals," Last Volume G-Z, 315 (1990)
Han HJ, Jo OS, "Study on Evaluation of Emission and Reduction Technology on VOC Discharge Sources," Kor. Petroleum Assoc. (1996)
KOSHA, "Design Guide of VOC Control Construction (Anyeon 98-17-248)," (2000)
Tang HM, Hwang SJ, J. Air Waste Manage. Assoc., 46, 349 (1996)
Sorial GA, Smith FL, Suidan MT, Pandit A, Biswas P, Brenner RC, J. Environ. Eng.-ASCE, 123(6), 530 (1997)
Zhao W, "Biodegradation of Volatile Organic Compounds (Benzene, Toluene, Xylene) in Biofilter," Ph.D. Dissertation, University of Washington, Washington, U.S.A., 55-110 (1996)
Bielefeldt AR, "Biotreatment of Contaminated Gases in a Sparged Suspended-Growth Reactor: Mass Transfer and Biodegradation Model," Ph.D. Dissertation, University of Washington, Washington, U.S.A., 4-55 (1996)
Park KJ, Yeom JS, J. Environ. Hi-Technol., 102 (1999)
Park SJ, Lim JS, Theor. Appl. Chem. Eng., 5(2), 3437 (1999)
Park SJ, J. Environ. Hi-Technol., 28 (1999)
Lee MG, Kang JH, Kang YJ, HWAHAK KONGHAK, 30(6), 731 (1992)
Lee MG, Suh KH, J. Korean Environ. Sci. Soc., 5(2), 195 (1996)
Lee MG, Bin JI, Lee BH, Kim JK, Choi H, Kwon SH, HWAHAK KONGHAK, 39(3), 379 (2001)
Cho KS, Ryu HW, Lee NY, J. Biosci. Bioeng., 90(1), 25 (2000)
Deshusess MA, J. Environ. Eng.-ASCE, 563 (1997)
Martin GT, Loehr RC, J. Air. Waste Manage. Assoc., 46, 539 (1996)
Corsi RL, Seed L, Environ. Prog., 14, 151 (1995)
Zhou Q, Huang YL, Tseng DH, Shim H, Yang ST, J. Chem. Technol. Biotechnol., 73(4), 359 (1998) 
Sene L, Converti A, Felipe MGA, Zilli M, Bioresour. Technol., 83(2), 153 (2002) 
Kennes C, Cox HH, Doddema HJ, Harder W, J. Chem. Technol. Biotechnol., 66(3), 300 (1996) 
Lu C, Lin MR, Chu C, Adv. Environ. Res., 6, 99 (2002) 
Oh YS, Bartha R, J. Microbiol. Biotechnol., 13(6), 627 (1997)
Atlas RM, Bartha R, "Handbook of Microbiological Media," CRC Press, Boca Raton, FL (1995)
Ottengraf SPP, Rehm HJ, Reed G, "Exhaust Gas Purification," Biotechnology, vol. 8, VCH Verlagsgesellschaft, Wenheim, 425-452 (1986)
Hartenstein HV, "Biofiltration and Odor Control Technology for a Wastewater Treatment Plant," M.S. Thesis, Univ. of Florida, Gainsville, FL (1987)
Leson G, Winer AM, J. Air Waste Manage. Assoc., 41, 1045 (1991)
Kiared LB, Brzezinski R, Viel G, Heitz M, Environ. Prog., 15(3), 148 (1996)
Shareefdeen Z, Baltzis BC, Chem. Eng. Sci., 49(24), 4347 (1994)
Lim JS, Koo JK, Park SJ, J. Korean Soc. Atmosph. Environ., 14(6), 599 (1998)
Namkoong W, Park YJ, Park JS, J. Korean Solid Waste Eng. Soc., 17(8), 969 (2000)
Ottengraf SPP, Oever VD, Biotechnol. Bioeng., 25, 3089 (1983) 

The Korean Institute of Chemical Engineers. F5, 119, Anam-ro, Seongbuk-gu, 233 Spring Street Seoul 02856, South Korea.
Phone No. +82-2-458-3078FAX No. +82-507-804-0669E-mail : kiche@kiche.or.kr

Copyright (C) KICHE.all rights reserved.

- Korean Chemical Engineering Research 상단으로